The presence of ochratoxin A (OTA) in different food commodities deserves great attention because of its toxic and carcinogenic effects on humans and animals. In this paper, we report on the detection of OTA both in standard solutions and in contaminated samples of red wine by using amorphous silicon photosensors. The method relies on the excitation by ultraviolet radiation of the toxin molecules and on the absorption of the toxin reemitted light by the photosensor. The device is a p-i-n stacked structure, whose electro-optical characteristics have been optimized in order to maximize the photosensor responsivity and the limit of detection. For standard solutions, we found minimum detected OTA amount to be equal to 0.1 ng, while for contaminated red wine samples the technique coupled with very simplified and rapid extraction procedures has allowed the detection of OTA at the 1-ppb level.

Amorphous Silicon Photosensors for Detection of Ochratoxin A in Wine / Caputo, Domenico; DE CESARE, Giampiero; Fanelli, Corrado; Nascetti, Augusto; Alessandra, Ricelli; Scipinotti, Riccardo. - In: IEEE SENSORS JOURNAL. - ISSN 1530-437X. - ELETTRONICO. - 12:8(2012), pp. 2674-2679. [10.1109/jsen.2012.2198462]

Amorphous Silicon Photosensors for Detection of Ochratoxin A in Wine

CAPUTO, Domenico;DE CESARE, Giampiero;FANELLI, Corrado;NASCETTI, Augusto;SCIPINOTTI, RICCARDO
2012

Abstract

The presence of ochratoxin A (OTA) in different food commodities deserves great attention because of its toxic and carcinogenic effects on humans and animals. In this paper, we report on the detection of OTA both in standard solutions and in contaminated samples of red wine by using amorphous silicon photosensors. The method relies on the excitation by ultraviolet radiation of the toxin molecules and on the absorption of the toxin reemitted light by the photosensor. The device is a p-i-n stacked structure, whose electro-optical characteristics have been optimized in order to maximize the photosensor responsivity and the limit of detection. For standard solutions, we found minimum detected OTA amount to be equal to 0.1 ng, while for contaminated red wine samples the technique coupled with very simplified and rapid extraction procedures has allowed the detection of OTA at the 1-ppb level.
2012
chemical analysis; microsensors; amorphous silicon
01 Pubblicazione su rivista::01a Articolo in rivista
Amorphous Silicon Photosensors for Detection of Ochratoxin A in Wine / Caputo, Domenico; DE CESARE, Giampiero; Fanelli, Corrado; Nascetti, Augusto; Alessandra, Ricelli; Scipinotti, Riccardo. - In: IEEE SENSORS JOURNAL. - ISSN 1530-437X. - ELETTRONICO. - 12:8(2012), pp. 2674-2679. [10.1109/jsen.2012.2198462]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/459025
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 23
social impact