In this investigation an electochemical cell has been designed for the direct measurement of silicon content in hot metal. Data of EMF vs. Si concentration have been obtained in Fe-Si-Csat melts at 1500°C, for Si content from 0.05 to 1.2%. Experimental values agree fairly well with EMF values calculated from thermodynamic data. Owing to its sensitivity and long working life the sensor can be used for continuous, long term measurement in hot metal.

NEW ELECTROCHEMICAL PROBE FOR SILICON DETERMINATION IN HOT METAL / Buiarelli, Francesca; Francesca, ; Paolo, Granati. - In: STEEL RESEARCH. - ISSN 0177-4832. - STAMPA. - 61:2(1990), pp. 60-63.

NEW ELECTROCHEMICAL PROBE FOR SILICON DETERMINATION IN HOT METAL

BUIARELLI, Francesca;
1990

Abstract

In this investigation an electochemical cell has been designed for the direct measurement of silicon content in hot metal. Data of EMF vs. Si concentration have been obtained in Fe-Si-Csat melts at 1500°C, for Si content from 0.05 to 1.2%. Experimental values agree fairly well with EMF values calculated from thermodynamic data. Owing to its sensitivity and long working life the sensor can be used for continuous, long term measurement in hot metal.
1990
01 Pubblicazione su rivista::01a Articolo in rivista
NEW ELECTROCHEMICAL PROBE FOR SILICON DETERMINATION IN HOT METAL / Buiarelli, Francesca; Francesca, ; Paolo, Granati. - In: STEEL RESEARCH. - ISSN 0177-4832. - STAMPA. - 61:2(1990), pp. 60-63.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/458960
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
social impact