Objectives: To compare vascular and parenchymal contrast enhancement in multidetector computed tomography of the liver using two contrast media with different iodine concentration (Iodixanol 320 mgI/mL and Iomeprol 400 mgI/mL) and similar viscosity, using fixed total iodine volume (40 gI) and iodine delivery rate (1.6 gI/s). Methods: 110 patients were prospectively randomized into two groups. Group A received 125 mL of Iodixanol 320 and group B 100 mL of Iomeprol 400. Attenuation values were measured at the level of the aorta, portal vein and liver parenchyma on unenhanced, arterial, portal and equilibrium phases. A non inferiority test was performed on the differences between the two groups. An independent reader evaluated image quality. Results: The equivalence of the two CM was demonstrated in all measurements. Higher, but not statistically significant, attenuation values were obtained with Iomeprol 400 in the aorta during the arterial phase (305.3 HU versus 288.4 HU; P = 0.32) and with Iodixanol 320 in the liver parenchyma, during both portal (59.8 HU versus 65.5 HU; P = 0.78) and equilibrium (40.4 HU versus 41.8 HU; P = 0.55) phases. Conclusions: Iodixanol 320 and Iomeprol 400 injected at the same iodine delivery rate (1.6 gI/s) and total iodine load (40 gI) did not provide statistically significant differences in liver parenchymal and vascular contrast enhancement. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

High concentration (400 mgI/mL) versus low concentration (320 mgI/mL) iodinated contrast media in multi detector computed tomography of the liver: A randomized, single centre, non-inferiority study / Rengo, Marco; Caruso, Damiano; DE CECCO, CARLO NICOLA; Lucchesi, Paola; Bellini, Davide; Maceroni, MARCO MARIA; Ferrari, Riccardo; Paolantonio, Pasquale; Franco, Iafrate; Carbone, Iacopo; Vecchietti, Fabrizio; Laghi, Andrea. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - ELETTRONICO. - 81:11(2012), pp. 3096-3101. [10.1016/j.ejrad.2012.05.017]

High concentration (400 mgI/mL) versus low concentration (320 mgI/mL) iodinated contrast media in multi detector computed tomography of the liver: A randomized, single centre, non-inferiority study

RENGO, MARCO;CARUSO, DAMIANO;DE CECCO, CARLO NICOLA;LUCCHESI, PAOLA;BELLINI, DAVIDE;MACERONI, MARCO MARIA;FERRARI, Riccardo;PAOLANTONIO, PASQUALE;CARBONE, IACOPO;VECCHIETTI, FABRIZIO;LAGHI, ANDREA
2012

Abstract

Objectives: To compare vascular and parenchymal contrast enhancement in multidetector computed tomography of the liver using two contrast media with different iodine concentration (Iodixanol 320 mgI/mL and Iomeprol 400 mgI/mL) and similar viscosity, using fixed total iodine volume (40 gI) and iodine delivery rate (1.6 gI/s). Methods: 110 patients were prospectively randomized into two groups. Group A received 125 mL of Iodixanol 320 and group B 100 mL of Iomeprol 400. Attenuation values were measured at the level of the aorta, portal vein and liver parenchyma on unenhanced, arterial, portal and equilibrium phases. A non inferiority test was performed on the differences between the two groups. An independent reader evaluated image quality. Results: The equivalence of the two CM was demonstrated in all measurements. Higher, but not statistically significant, attenuation values were obtained with Iomeprol 400 in the aorta during the arterial phase (305.3 HU versus 288.4 HU; P = 0.32) and with Iodixanol 320 in the liver parenchyma, during both portal (59.8 HU versus 65.5 HU; P = 0.78) and equilibrium (40.4 HU versus 41.8 HU; P = 0.55) phases. Conclusions: Iodixanol 320 and Iomeprol 400 injected at the same iodine delivery rate (1.6 gI/s) and total iodine load (40 gI) did not provide statistically significant differences in liver parenchymal and vascular contrast enhancement. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
2012
liver imaging; parenchymal contrast enhancement; contrast media; vascular contrast enhancement
01 Pubblicazione su rivista::01a Articolo in rivista
High concentration (400 mgI/mL) versus low concentration (320 mgI/mL) iodinated contrast media in multi detector computed tomography of the liver: A randomized, single centre, non-inferiority study / Rengo, Marco; Caruso, Damiano; DE CECCO, CARLO NICOLA; Lucchesi, Paola; Bellini, Davide; Maceroni, MARCO MARIA; Ferrari, Riccardo; Paolantonio, Pasquale; Franco, Iafrate; Carbone, Iacopo; Vecchietti, Fabrizio; Laghi, Andrea. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - ELETTRONICO. - 81:11(2012), pp. 3096-3101. [10.1016/j.ejrad.2012.05.017]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/457193
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 15
social impact