A method for measuring directly the ammonia concentration in plasma by the use of an ammonia gas sensitive electrode is proposed. The plasma pH is brought to a final value of 10.4; at which pH, no NH3 is released from other sources and the amount of NH3 measured is 92% of the total ammonia (pKa = 9.3). The potentiometric readings of the samples are referred to a standard curve. In normal subjects, the mean values of venous ammonia nitrogen are 23.9 ± 9.6 (SD) μg/100 ml of plasma. Reproducibility is ± 0.5 mV, or 2%. The method was also compared to the ion exchange method: The difference was constantly below 3%. The time required for the assay is less than 10 min. The method, when compared to others adopting the same electrode, is recommended for its simplicity, accuracy, and rapidity. © 1975.

Rapid determination of plasma ammonia using an ion specific electrode / Attili, Adolfo Francesco; D., Autizi; Capocaccia, Livio. - In: BIOCHEMICAL MEDICINE. - ISSN 0006-2944. - STAMPA. - 14:1(1975), pp. 109-116.

Rapid determination of plasma ammonia using an ion specific electrode

ATTILI, Adolfo Francesco;CAPOCACCIA, Livio
1975

Abstract

A method for measuring directly the ammonia concentration in plasma by the use of an ammonia gas sensitive electrode is proposed. The plasma pH is brought to a final value of 10.4; at which pH, no NH3 is released from other sources and the amount of NH3 measured is 92% of the total ammonia (pKa = 9.3). The potentiometric readings of the samples are referred to a standard curve. In normal subjects, the mean values of venous ammonia nitrogen are 23.9 ± 9.6 (SD) μg/100 ml of plasma. Reproducibility is ± 0.5 mV, or 2%. The method was also compared to the ion exchange method: The difference was constantly below 3%. The time required for the assay is less than 10 min. The method, when compared to others adopting the same electrode, is recommended for its simplicity, accuracy, and rapidity. © 1975.
1975
01 Pubblicazione su rivista::01a Articolo in rivista
Rapid determination of plasma ammonia using an ion specific electrode / Attili, Adolfo Francesco; D., Autizi; Capocaccia, Livio. - In: BIOCHEMICAL MEDICINE. - ISSN 0006-2944. - STAMPA. - 14:1(1975), pp. 109-116.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/451682
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 19
  • ???jsp.display-item.citation.isi??? ND
social impact