Objectives: To assess by means of push-out test the post retentive potential of a new flowable resin composite with low polymerization stress. Methods: SureFil (R) SDR (TM) (Dentsply, S) was compared with the resin cement Calibra (Dentsply, C). S and C were used in combination with the adhesive XP Bond (Dentsply, XPB). In C group the Self-Cure Activator was mixed with XPB. The following types of fibre posts were luted into 30 extracted premolars: Radix Fiber Post (Dentsply, R), DT Light Post (RTD, LP), ER Dentin Post (Komet, ER), DT Light SL (VDW, SL), FibreKleer (Jeneric Pentron, F). Six posted roots per group were tested. Each root provided three to five 1 mm-thick slices. Measured push-out strengths were differentiated by post space level and statistically analysed (p < 0.05). The failure mode of each debonded specimen was assessed. Results: Cement type did not have a significant effect on post retention (p = 0.54). Post type was a significant factor for push-out strength (p < 0.001). LP exhibited significantly higher retentive strength than SL and F; push-out strengths of ER and R were significantly higher than those of F. Post retention was significantly influenced by post space level (p < 0.001). Significantly higher push-out strengths were recorded at the coronal third than at the middle and apical levels. The post-cement interaction was significant (p = 0.002). Posts luted with S most often failed at the cement-post interface. Conclusions: When the new flowable low-stress composite was used to lute fibre posts, similar retentive strengths to those of a marketed cement from the same manufacturer were achieved. Clinical significance: SureFil (R) SDR (TM), a flowable composite originally proposed for bulk filling of posterior restorations, exhibited post retentive strengths similar to those of a cement by the same manufacturer. With a relatively high filler load, yet a low curing stress, SureFil (R) SDR (TM) may be adequate for both post cementation and core build-up. (C) 2012 Elsevier Ltd. All rights reserved.

Post retentive ability of a new resin composite with low stress behaviour / Agostino, Giovannetti; Cecilia, Goracci; Alessandro, Vichi; Nicoletta, Chieffi; Polimeni, Antonella; Marco, Ferrari. - In: JOURNAL OF DENTISTRY. - ISSN 0300-5712. - STAMPA. - 40:4(2012), pp. 322-328. [10.1016/j.jdent.2012.01.007]

Post retentive ability of a new resin composite with low stress behaviour

POLIMENI, Antonella;
2012

Abstract

Objectives: To assess by means of push-out test the post retentive potential of a new flowable resin composite with low polymerization stress. Methods: SureFil (R) SDR (TM) (Dentsply, S) was compared with the resin cement Calibra (Dentsply, C). S and C were used in combination with the adhesive XP Bond (Dentsply, XPB). In C group the Self-Cure Activator was mixed with XPB. The following types of fibre posts were luted into 30 extracted premolars: Radix Fiber Post (Dentsply, R), DT Light Post (RTD, LP), ER Dentin Post (Komet, ER), DT Light SL (VDW, SL), FibreKleer (Jeneric Pentron, F). Six posted roots per group were tested. Each root provided three to five 1 mm-thick slices. Measured push-out strengths were differentiated by post space level and statistically analysed (p < 0.05). The failure mode of each debonded specimen was assessed. Results: Cement type did not have a significant effect on post retention (p = 0.54). Post type was a significant factor for push-out strength (p < 0.001). LP exhibited significantly higher retentive strength than SL and F; push-out strengths of ER and R were significantly higher than those of F. Post retention was significantly influenced by post space level (p < 0.001). Significantly higher push-out strengths were recorded at the coronal third than at the middle and apical levels. The post-cement interaction was significant (p = 0.002). Posts luted with S most often failed at the cement-post interface. Conclusions: When the new flowable low-stress composite was used to lute fibre posts, similar retentive strengths to those of a marketed cement from the same manufacturer were achieved. Clinical significance: SureFil (R) SDR (TM), a flowable composite originally proposed for bulk filling of posterior restorations, exhibited post retentive strengths similar to those of a cement by the same manufacturer. With a relatively high filler load, yet a low curing stress, SureFil (R) SDR (TM) may be adequate for both post cementation and core build-up. (C) 2012 Elsevier Ltd. All rights reserved.
2012
failure mode; low-stress; luting; post; push-out; resin composite
01 Pubblicazione su rivista::01a Articolo in rivista
Post retentive ability of a new resin composite with low stress behaviour / Agostino, Giovannetti; Cecilia, Goracci; Alessandro, Vichi; Nicoletta, Chieffi; Polimeni, Antonella; Marco, Ferrari. - In: JOURNAL OF DENTISTRY. - ISSN 0300-5712. - STAMPA. - 40:4(2012), pp. 322-328. [10.1016/j.jdent.2012.01.007]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/446758
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 18
social impact