A 2 month-old boy was admitted to the authors' hospital because of regurgitation and persistent cough during breastfeeding. A chest X-ray examination and a barium esophagogram disclosed small amounts of barium passing in the trachea, suggesting a tracheoesophageal fistula (TEF). Bronchoscopy combined with upper gastrointestinal (GI) endoscopy performed with the patient under general anesthesia confirmed the fistula. The TEF was treated by injection of 1 ml Glubran 2 from the esophageal side. A nasogastric tube was placed for feedings, and 7 days later, a barium esophagogram showed a reduction of caliber but not complete closure of the TEF. Unsuccessful fistula obliteration with Glubran was attributed to technical difficulties in catheterization of the fistula orifice, mainly resulting from its close proximity to the upper esophageal sphincter and to its small caliber. Therefore, an argon plasma coagulator (APC) probe with a circumferentially oriented nozzle was used from the esophageal side as an alternative technique to fulgurate the residual fistula orifice (see video). A nasogastric tube was placed for feedings. Oral feeding was started 7 days later when a barium esophagogram confirmed complete fistula closure. At the 2-year follow-up visit, the boy was asymptomatic, and the barium esophagogram was negative. This report describes a case in which esophagoscopy gave a clear view of the fistula due to its direction from esophagus to trachea. Complete fistula obliteration was not obtained with Glubran. However, APC was successfully used to close the residual fistula orifice. The authors suggest that APC can be used as an alternative endoscopic technique to repair TEF when other techniques fail.

Argon plasma coagulator in a 2-month-old child with tracheoesophageal fistula / DI NARDO, Giovanni; Oliva, Salvatore; Barbato, Maria; Aloi, Marina; Midulla, Fabio; Roggini, Mario; Valitutti, Francesco; Frediani, Simone; Cucchiara, Salvatore. - In: SURGICAL ENDOSCOPY. - ISSN 0930-2794. - 26:9(2012), pp. 2678-2680. [10.1007/s00464-012-2214-7]

Argon plasma coagulator in a 2-month-old child with tracheoesophageal fistula

DI NARDO, Giovanni;OLIVA, SALVATORE;BARBATO, Maria;ALOI, MARINA;MIDULLA, Fabio;ROGGINI, Mario;VALITUTTI, FRANCESCO;FREDIANI, SIMONE;CUCCHIARA, Salvatore
2012

Abstract

A 2 month-old boy was admitted to the authors' hospital because of regurgitation and persistent cough during breastfeeding. A chest X-ray examination and a barium esophagogram disclosed small amounts of barium passing in the trachea, suggesting a tracheoesophageal fistula (TEF). Bronchoscopy combined with upper gastrointestinal (GI) endoscopy performed with the patient under general anesthesia confirmed the fistula. The TEF was treated by injection of 1 ml Glubran 2 from the esophageal side. A nasogastric tube was placed for feedings, and 7 days later, a barium esophagogram showed a reduction of caliber but not complete closure of the TEF. Unsuccessful fistula obliteration with Glubran was attributed to technical difficulties in catheterization of the fistula orifice, mainly resulting from its close proximity to the upper esophageal sphincter and to its small caliber. Therefore, an argon plasma coagulator (APC) probe with a circumferentially oriented nozzle was used from the esophageal side as an alternative technique to fulgurate the residual fistula orifice (see video). A nasogastric tube was placed for feedings. Oral feeding was started 7 days later when a barium esophagogram confirmed complete fistula closure. At the 2-year follow-up visit, the boy was asymptomatic, and the barium esophagogram was negative. This report describes a case in which esophagoscopy gave a clear view of the fistula due to its direction from esophagus to trachea. Complete fistula obliteration was not obtained with Glubran. However, APC was successfully used to close the residual fistula orifice. The authors suggest that APC can be used as an alternative endoscopic technique to repair TEF when other techniques fail.
2012
argon plasma coagulator; tef; tracheoesophageal fistula
01 Pubblicazione su rivista::01a Articolo in rivista
Argon plasma coagulator in a 2-month-old child with tracheoesophageal fistula / DI NARDO, Giovanni; Oliva, Salvatore; Barbato, Maria; Aloi, Marina; Midulla, Fabio; Roggini, Mario; Valitutti, Francesco; Frediani, Simone; Cucchiara, Salvatore. - In: SURGICAL ENDOSCOPY. - ISSN 0930-2794. - 26:9(2012), pp. 2678-2680. [10.1007/s00464-012-2214-7]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/442630
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 5
social impact