We performed a randomized study to compare internal thoracic artery (ITA) flow response to two harvesting methods used in the skeletonization procedure: ultrasonic scalpel and bipolar electrocautery. Sixty patients scheduled for CABG were randomized to receive either ultrasonically (ns30 patients) or electrocautery (ns30 patients) skeletonized ITAs. Intraoperative ITA graft mean flows were obtained with a transit-time flowmeter. ITA flows were evaluated at the beginning (Time 1) and at the end (Time 2) of the harvesting procedure. Post-cardiopulmonary bypass (CPB) flow measurement (Time 3) was obtained in the ITA grafts anastomosed to the left anterior descending artery. Intraoperative mean flow decreased significantly within ultrasonic group (Group U) and electrocautery group (Group E) at the end of the harvesting procedure (P-0.0001 in both cases). Within both groups the final mean flow measured on anastomosed ITAs (Time 3) was significantly higher than the beginning ITA flow value (Time 1). No statistical difference was noted comparing ITA flows between the two groups at any time of evaluation. Skeletonization harvesting of the ITA produces a modification of the mean flow. The quantity and the reversibility of this phenomenon, probably related to vasospasm, are independent from the energy source used in the skeletonization procedure.

Skeletonization of the internal thoracic artery: a randomized comparison of harvesting methods / Urso, S; Alvarez, L; Sádaba, R; Greco, Ernesto. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9285. - STAMPA. - nov 12:(2007), pp. 23-26. [10.1510/icvts.2007.168831]

Skeletonization of the internal thoracic artery: a randomized comparison of harvesting methods.

GRECO, Ernesto
2007

Abstract

We performed a randomized study to compare internal thoracic artery (ITA) flow response to two harvesting methods used in the skeletonization procedure: ultrasonic scalpel and bipolar electrocautery. Sixty patients scheduled for CABG were randomized to receive either ultrasonically (ns30 patients) or electrocautery (ns30 patients) skeletonized ITAs. Intraoperative ITA graft mean flows were obtained with a transit-time flowmeter. ITA flows were evaluated at the beginning (Time 1) and at the end (Time 2) of the harvesting procedure. Post-cardiopulmonary bypass (CPB) flow measurement (Time 3) was obtained in the ITA grafts anastomosed to the left anterior descending artery. Intraoperative mean flow decreased significantly within ultrasonic group (Group U) and electrocautery group (Group E) at the end of the harvesting procedure (P-0.0001 in both cases). Within both groups the final mean flow measured on anastomosed ITAs (Time 3) was significantly higher than the beginning ITA flow value (Time 1). No statistical difference was noted comparing ITA flows between the two groups at any time of evaluation. Skeletonization harvesting of the ITA produces a modification of the mean flow. The quantity and the reversibility of this phenomenon, probably related to vasospasm, are independent from the energy source used in the skeletonization procedure.
2007
01 Pubblicazione su rivista::01a Articolo in rivista
Skeletonization of the internal thoracic artery: a randomized comparison of harvesting methods / Urso, S; Alvarez, L; Sádaba, R; Greco, Ernesto. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9285. - STAMPA. - nov 12:(2007), pp. 23-26. [10.1510/icvts.2007.168831]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/44262
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact