Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the data. The methods have been tested on cosmic ray muon data, calorimeter noise data, and single beam data collected with CMS in 2008. The noise rejection algorithms can be applied to LHC collision data at the trigger level or in the offline analysis. The application of the algorithms at the trigger level is shown to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the CMS physics trigger operation. © 2010 IOP Publishing Ltd and SISSA.

Identification and filtering of uncharacteristic noise in the CMS hadron calorimeter / Chatrchyan, S., Khachatryan, V., Sirunyan, A.m., Adam, W., Arnold, B., Bergauer, H., Bergauer, T., Dragicevic, M., Eichberger, M., Ero, J., Friedl, M., Fruhwirth, R., Ghete, V.m., Hammer, J., Hansel, S., Hoch, M., Hormann, N., Hrubec, J., Jeitler, M., Kasieczka, G., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 5:3(2010), pp. T03014-T03014. [10.1088/1748-0221/5/03/t03014]

Identification and filtering of uncharacteristic noise in the CMS hadron calorimeter

BARONE, Luciano Maria;DEL RE, Daniele;LONGO, Egidio;ORGANTINI, Giovanni;PARAMATTI, Riccardo;RAHATLOU, SHAHRAM;TRACZYK, PIOTR WOJCIECH;SANTANASTASIO, FRANCESCO;
2010

Abstract

Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the data. The methods have been tested on cosmic ray muon data, calorimeter noise data, and single beam data collected with CMS in 2008. The noise rejection algorithms can be applied to LHC collision data at the trigger level or in the offline analysis. The application of the algorithms at the trigger level is shown to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the CMS physics trigger operation. © 2010 IOP Publishing Ltd and SISSA.
2010
01 Pubblicazione su rivista::01a Articolo in rivista
Identification and filtering of uncharacteristic noise in the CMS hadron calorimeter / Chatrchyan, S., Khachatryan, V., Sirunyan, A.m., Adam, W., Arnold, B., Bergauer, H., Bergauer, T., Dragicevic, M., Eichberger, M., Ero, J., Friedl, M., Fruhwirth, R., Ghete, V.m., Hammer, J., Hansel, S., Hoch, M., Hormann, N., Hrubec, J., Jeitler, M., Kasieczka, G., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 5:3(2010), pp. T03014-T03014. [10.1088/1748-0221/5/03/t03014]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/44173
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 82
  • ???jsp.display-item.citation.isi??? 81
social impact