Objective: To analyze the forces released by four types of passive stainless steel self-ligating brackets (SLBs), and by two nonconventional elastomeric ligature-bracket systems when compared with conventional elastomeric ligatures on conventional stainless steel brackets during the alignment of apically displaced teeth at the maxillary arch. Materials and Methods: An experimental model consisting of five brackets was used to assess the forces released by the seven different ligature-bracket systems with 0.012" or 0.014" super- elastic nickel titanium wire in the presence of different amounts of apical displacement of the canine (ranging from 1.5 mm to 6 mm). Comparisons between the different types of bracket/wire/ ligature systems were carried out by means of ANOVA on ranks with Dunnett's post hoc test (P < .05). Results: When correction of a misalignment greater than 3 mm is attempted, a noticeable amount of force for alignment is generated by passive SLBs and nonconventional elastomeric ligature- bracket systems, and a null amount of force is released in the presence of conventional elasto- meric ligatures on conventional brackets. Conclusions: When minimal apical displacement is needed (1.5 mm), the differences in performance between low-friction and conventional systems are minimal. These differences become significant when correction of a misalignment of greater than 3.0 mm is attempted. © 2009 by The EH Angle Education and Research Foundation, Inc.
Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth / Tiziano, Baccetti; Lorenzo, Franchi; Matteo, Camporesi; Efisio, Defraia; Barbato, Ersilia. - In: ANGLE ORTHODONTIST. - ISSN 0003-3219. - STAMPA. - 79:3(2009), pp. 533-539. [10.2319/050508-249.1]
Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth
BARBATO, Ersilia
2009
Abstract
Objective: To analyze the forces released by four types of passive stainless steel self-ligating brackets (SLBs), and by two nonconventional elastomeric ligature-bracket systems when compared with conventional elastomeric ligatures on conventional stainless steel brackets during the alignment of apically displaced teeth at the maxillary arch. Materials and Methods: An experimental model consisting of five brackets was used to assess the forces released by the seven different ligature-bracket systems with 0.012" or 0.014" super- elastic nickel titanium wire in the presence of different amounts of apical displacement of the canine (ranging from 1.5 mm to 6 mm). Comparisons between the different types of bracket/wire/ ligature systems were carried out by means of ANOVA on ranks with Dunnett's post hoc test (P < .05). Results: When correction of a misalignment greater than 3 mm is attempted, a noticeable amount of force for alignment is generated by passive SLBs and nonconventional elastomeric ligature- bracket systems, and a null amount of force is released in the presence of conventional elasto- meric ligatures on conventional brackets. Conclusions: When minimal apical displacement is needed (1.5 mm), the differences in performance between low-friction and conventional systems are minimal. These differences become significant when correction of a misalignment of greater than 3.0 mm is attempted. © 2009 by The EH Angle Education and Research Foundation, Inc.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.