Although many thrombectomy devices have been tested in ST-segment elevation acute myocardial infarction (STEMI), there are no comparative data on safety or effectiveness in thrombectomy or ST-segment resolution. This study compares manual versus nonmanual thrombectomy devices in patients undergoing primary or rescue percutaneous coronary intervention in a tertiary care center. We identified 232 consecutive patients with STEMI and time from symptom onset to emergency room contact of 12 h undergoing percutaneous coronary intervention with coronary thrombectomy devices. Primary end point was ST-segment resolution of >= 70%. Several angiographic, procedural and clinical secondary end points were also evaluated. The manual thrombectomy group included 110 patients and the nonmanual group 122 patients. Both groups were similar in their clinical characteristics. The primary end point occurred with similar frequency in patients treated with manual versus nonmanual thrombectomy (67.9% vs 60.0%, P = 0.216). No significant differences were found in the two groups with regard to procedural complications, angiographic reperfusion parameters, in-hospital major adverse cardiac events, or infarct size, whereas manual thrombectomy was associated with a better left ventricle ejection fraction at discharge. Furthermore, treatment with a manual thrombectomy device was associated with significantly shorter procedural times (69 min vs 95 min, P < 0.001) and lower procedural costs (2981 euros vs 7505 euros, P < 0.001). The use of manual thrombus-aspiration catheters appeared equivalent to nonmanual thrombectomy devices in the setting of primary or rescue percutaneous intervention in terms of clinical efficacy, and led to shorter procedures and cost savings.

Manual versus nonmanual thrombectomy in primary and rescue percutaneous coronary angioplasty / Giandomenico, Tarsia; M., De Michele; Domenico, Polosa; BIONDI ZOCCAI, Giuseppe; Fabio, Costantino; G., Del Prete; Rocco Aldo, Osanna; Pasquale, Innelli; Francesco, Sisto; Imad, Sheiban; Pasquale, Lisanti. - In: HEART AND VESSELS. - ISSN 0910-8327. - 25:4(2010), pp. 275-281. [10.1007/s00380-009-1198-2]

Manual versus nonmanual thrombectomy in primary and rescue percutaneous coronary angioplasty

BIONDI ZOCCAI, GIUSEPPE;
2010

Abstract

Although many thrombectomy devices have been tested in ST-segment elevation acute myocardial infarction (STEMI), there are no comparative data on safety or effectiveness in thrombectomy or ST-segment resolution. This study compares manual versus nonmanual thrombectomy devices in patients undergoing primary or rescue percutaneous coronary intervention in a tertiary care center. We identified 232 consecutive patients with STEMI and time from symptom onset to emergency room contact of 12 h undergoing percutaneous coronary intervention with coronary thrombectomy devices. Primary end point was ST-segment resolution of >= 70%. Several angiographic, procedural and clinical secondary end points were also evaluated. The manual thrombectomy group included 110 patients and the nonmanual group 122 patients. Both groups were similar in their clinical characteristics. The primary end point occurred with similar frequency in patients treated with manual versus nonmanual thrombectomy (67.9% vs 60.0%, P = 0.216). No significant differences were found in the two groups with regard to procedural complications, angiographic reperfusion parameters, in-hospital major adverse cardiac events, or infarct size, whereas manual thrombectomy was associated with a better left ventricle ejection fraction at discharge. Furthermore, treatment with a manual thrombectomy device was associated with significantly shorter procedural times (69 min vs 95 min, P < 0.001) and lower procedural costs (2981 euros vs 7505 euros, P < 0.001). The use of manual thrombus-aspiration catheters appeared equivalent to nonmanual thrombectomy devices in the setting of primary or rescue percutaneous intervention in terms of clinical efficacy, and led to shorter procedures and cost savings.
2010
acute myocardial infarction; percutaneous transluminal coronary angioplasty; thrombectomy
01 Pubblicazione su rivista::01a Articolo in rivista
Manual versus nonmanual thrombectomy in primary and rescue percutaneous coronary angioplasty / Giandomenico, Tarsia; M., De Michele; Domenico, Polosa; BIONDI ZOCCAI, Giuseppe; Fabio, Costantino; G., Del Prete; Rocco Aldo, Osanna; Pasquale, Innelli; Francesco, Sisto; Imad, Sheiban; Pasquale, Lisanti. - In: HEART AND VESSELS. - ISSN 0910-8327. - 25:4(2010), pp. 275-281. [10.1007/s00380-009-1198-2]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/434378
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 12
social impact