Plotino G, Grande NM, Testarelli L, Gambarini G. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments. International Endodontic Journal, 45, 614618, 2012. Abstract Aim To evaluate the cyclic fatigue resistance of Reciproc (R) and WaveOne (R) instruments in simulated root canals. Methodology Two groups of 15 NiTi endodontic instruments of identical tip size of 0.25 mm were tested, group A; Reciproc (R) R25 and group B: WaveOne (R) primary. Cyclic fatigue testing was performed in a stainless steel artificial canal manufactured by reproducing the instruments size and taper. A simulated root canal with a 60 degrees angle of curvature and 5-mm radius of curvature was constructed for both the instruments tested. The centre of the curvature was 5 mm from the tip of the instrument and the curved segment of the canal was approximately 5 mm in length. The Reciproc (R) instruments were activated using the preset programme specific for the Reciproc (R) instruments, whilst the WaveOne (R) instruments were activated using the preset programme specific for the WaveOne (R) instruments. All instruments were rotated until fracture occurred and the time to fracture (TtF) and the length of the fractured tip were recorded and registered. Means and standard deviations of TtF and fragment length were calculated for each system and data were subjected to Students t-test (P < 0.05). Results A statistically significant difference (P < 0.05) was noted between Reciproc (R) and WaveOne (R) instruments. Reciproc (R) R25 instruments were associated with a significant increase in the mean time to fracture when compared with primary WaveOne (R) instruments (130.8 +/- 18.4 vs. 97.8 +/- 15.9 s). There was no significant difference (P > 0.05) in the mean length of the fractured fragments between the instruments. Conclusions Reciproc (R) instruments were associated with a significantly higher cyclic fatigue resistance than WaveOne (R) instruments.

Cyclic fatigue of Reciproc and WaveOne reciprocating instruments / G., Plotino; Grande, NICOLA MARIA; Testarelli, Luca; Gambarini, Gianluca. - In: INTERNATIONAL ENDODONTIC JOURNAL. - ISSN 0143-2885. - 45:7(2012), pp. 614-618. [10.1111/j.1365-2591.2012.02015.x]

Cyclic fatigue of Reciproc and WaveOne reciprocating instruments

GRANDE, NICOLA MARIA;TESTARELLI, Luca;GAMBARINI, Gianluca
2012

Abstract

Plotino G, Grande NM, Testarelli L, Gambarini G. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments. International Endodontic Journal, 45, 614618, 2012. Abstract Aim To evaluate the cyclic fatigue resistance of Reciproc (R) and WaveOne (R) instruments in simulated root canals. Methodology Two groups of 15 NiTi endodontic instruments of identical tip size of 0.25 mm were tested, group A; Reciproc (R) R25 and group B: WaveOne (R) primary. Cyclic fatigue testing was performed in a stainless steel artificial canal manufactured by reproducing the instruments size and taper. A simulated root canal with a 60 degrees angle of curvature and 5-mm radius of curvature was constructed for both the instruments tested. The centre of the curvature was 5 mm from the tip of the instrument and the curved segment of the canal was approximately 5 mm in length. The Reciproc (R) instruments were activated using the preset programme specific for the Reciproc (R) instruments, whilst the WaveOne (R) instruments were activated using the preset programme specific for the WaveOne (R) instruments. All instruments were rotated until fracture occurred and the time to fracture (TtF) and the length of the fractured tip were recorded and registered. Means and standard deviations of TtF and fragment length were calculated for each system and data were subjected to Students t-test (P < 0.05). Results A statistically significant difference (P < 0.05) was noted between Reciproc (R) and WaveOne (R) instruments. Reciproc (R) R25 instruments were associated with a significant increase in the mean time to fracture when compared with primary WaveOne (R) instruments (130.8 +/- 18.4 vs. 97.8 +/- 15.9 s). There was no significant difference (P > 0.05) in the mean length of the fractured fragments between the instruments. Conclusions Reciproc (R) instruments were associated with a significantly higher cyclic fatigue resistance than WaveOne (R) instruments.
2012
cyclic fatigue; nickel-titanium; reciprocation
01 Pubblicazione su rivista::01a Articolo in rivista
Cyclic fatigue of Reciproc and WaveOne reciprocating instruments / G., Plotino; Grande, NICOLA MARIA; Testarelli, Luca; Gambarini, Gianluca. - In: INTERNATIONAL ENDODONTIC JOURNAL. - ISSN 0143-2885. - 45:7(2012), pp. 614-618. [10.1111/j.1365-2591.2012.02015.x]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/432929
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 64
  • Scopus 190
  • ???jsp.display-item.citation.isi??? 160
social impact