We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 +/- 0.0032 (stat.) +/- 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments. (C) 2010 Published by Elsevier B.V.

Measurement of the charge ratio of atmospheric muons with the CMS detector / Khachatryan, V., Sirunyan, A.m., Tumasyan, A., Adam, W., Bergauer, T., Dragicevic, M., Ero, J., Fabjan, C., Friedl, M., Fruehwirth, R., Ghete, V.m., Hammer, J., Haensel, S., Hoch, M., Horemann, N., Hrubec, J., Jeitler, M., Kasieczka, G., Kiesenhofer, W., Krammer, M., et al.. - In: PHYSICS LETTERS. SECTION B. - ISSN 0370-2693. - 692:2(2010), pp. 83-104. [10.1016/j.physletb.2010.07.033]

Measurement of the charge ratio of atmospheric muons with the CMS detector

BARONE, Luciano Maria;DEL RE, Daniele;LONGO, Egidio;ORGANTINI, Giovanni;PARAMATTI, Riccardo;RAHATLOU, SHAHRAM;TRACZYK, PIOTR WOJCIECH;SANTANASTASIO, FRANCESCO;
2010

Abstract

We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 +/- 0.0032 (stat.) +/- 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments. (C) 2010 Published by Elsevier B.V.
2010
physics; charge ratio; cms; cosmic rays; muon
01 Pubblicazione su rivista::01a Articolo in rivista
Measurement of the charge ratio of atmospheric muons with the CMS detector / Khachatryan, V., Sirunyan, A.m., Tumasyan, A., Adam, W., Bergauer, T., Dragicevic, M., Ero, J., Fabjan, C., Friedl, M., Fruehwirth, R., Ghete, V.m., Hammer, J., Haensel, S., Hoch, M., Horemann, N., Hrubec, J., Jeitler, M., Kasieczka, G., Kiesenhofer, W., Krammer, M., et al.. - In: PHYSICS LETTERS. SECTION B. - ISSN 0370-2693. - 692:2(2010), pp. 83-104. [10.1016/j.physletb.2010.07.033]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/43125
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 57
  • ???jsp.display-item.citation.isi??? 55
social impact