An amperometric biosensor for the direct determination of L-glutamate was developed by chemical bonding of L-glutamate oxidase (GAO) on a carboxylic Nylon membrane with polyazetidine prepolymer (PAP), and using a hydrogen peroxide electrode as indicating sensor. The biosensor is specific for L-glutamate and the peculiar analytical properties (linearity range, reproducibility, accuracy) were experimentally determined. Furthermore, the same basic biosensor was also modified to be used and characterized for the direct determination of L-glutamine. This L-glutamine biosensor was obtained by coimmobilizing, on two separate membranes, glutamic acid oxidase and glutaminase (GMN) on the same biosensor. The two sensors were then used for the determination of glutamate and L-glutamine contained in pharmaceutical formulations and the results were compared with those obtained by other analytical methods.
DETERMINATION OF L-GLUTAMATE AND L-GLUTAMINE IN PHARMACEUTICAL FORMULATIONS BY AMPEROMETRIC L-GLUTAMATE OXIDASE BASED ENZYME SENSORS / Botre', Francesco; Claudio, Botre; Giampiero, Lorenti; Mazzei, Franco; Fernando, Porcelli; Scibona, Giancarlo. - In: JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS. - ISSN 0731-7085. - STAMPA. - 11:8(1993), pp. 679-686. [10.1016/0731-7085(93)80174-y]
DETERMINATION OF L-GLUTAMATE AND L-GLUTAMINE IN PHARMACEUTICAL FORMULATIONS BY AMPEROMETRIC L-GLUTAMATE OXIDASE BASED ENZYME SENSORS
BOTRE', Francesco;MAZZEI, Franco;SCIBONA, Giancarlo
1993
Abstract
An amperometric biosensor for the direct determination of L-glutamate was developed by chemical bonding of L-glutamate oxidase (GAO) on a carboxylic Nylon membrane with polyazetidine prepolymer (PAP), and using a hydrogen peroxide electrode as indicating sensor. The biosensor is specific for L-glutamate and the peculiar analytical properties (linearity range, reproducibility, accuracy) were experimentally determined. Furthermore, the same basic biosensor was also modified to be used and characterized for the direct determination of L-glutamine. This L-glutamine biosensor was obtained by coimmobilizing, on two separate membranes, glutamic acid oxidase and glutaminase (GMN) on the same biosensor. The two sensors were then used for the determination of glutamate and L-glutamine contained in pharmaceutical formulations and the results were compared with those obtained by other analytical methods.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.