One hundred and ten patients (179 eyes) with reduced visual acuity caused by different ocular disorders underwent visual rehabilitation with an instrument for biofeedback: improved biofeedback integrated system (Ibis). One hundred and fourteen eyes had age-related macular degeneration, 39 eyes had myopic macular degeneration, and 26 eyes were affected by different ocular disorders. A placebo training was developed on 34 patients (47 eyes). Thirty-three eyes had age-related macular degeneration and 15 eyes had myopic macular degeneration. Visual acuity was found to be improved in 130/179 eyes (72.62%). Mean visual acuity was 0.24 before training and 0.36 at the last follow-up. A review of the literature and possible mechanisms are discussed.

An instrument for biofeedback applied to vision / Dario, Giorgi; Contestabile, Maria Teresa; Pacella, Elena; BALACCO GABRIELI, Corrado. - In: APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK. - ISSN 1090-0586. - 30:4(2005), pp. 389-395. [10.1007/s10484-005-8424-1]

An instrument for biofeedback applied to vision

CONTESTABILE, Maria Teresa;PACELLA, Elena;BALACCO GABRIELI, Corrado
2005

Abstract

One hundred and ten patients (179 eyes) with reduced visual acuity caused by different ocular disorders underwent visual rehabilitation with an instrument for biofeedback: improved biofeedback integrated system (Ibis). One hundred and fourteen eyes had age-related macular degeneration, 39 eyes had myopic macular degeneration, and 26 eyes were affected by different ocular disorders. A placebo training was developed on 34 patients (47 eyes). Thirty-three eyes had age-related macular degeneration and 15 eyes had myopic macular degeneration. Visual acuity was found to be improved in 130/179 eyes (72.62%). Mean visual acuity was 0.24 before training and 0.36 at the last follow-up. A review of the literature and possible mechanisms are discussed.
2005
biofeedback; central scotoma; improved biofeedback integrated system (ibis); low vision; macular degeneration; visual rehabilitation
01 Pubblicazione su rivista::01a Articolo in rivista
An instrument for biofeedback applied to vision / Dario, Giorgi; Contestabile, Maria Teresa; Pacella, Elena; BALACCO GABRIELI, Corrado. - In: APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK. - ISSN 1090-0586. - 30:4(2005), pp. 389-395. [10.1007/s10484-005-8424-1]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/42533
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 21
social impact