We have studied the variations of the performances, and particularly the discrimination efficiency, of a BGO-CsI(Tl) phoswich detector in the temperature range 2.5–40°C. The scintillation decay time evaluation has been carried out by means of a double constant fraction discriminator and a time to amplitude converter on 1 μs shaped pulses. Good discrimination between BGO and CsI(Tl) events has been obtained over the whole temperature range, even though small efficiency variations are present because of the relative displacement of the acceptance window of the discriminator due to the decay time dependence on temperature. A criterium to minimize this effect, useful in particular for the BGO-CsI(Tl) phoswich, has been developed.

Temperature dependence of a BGO-CsI(Tl) phoswich detector properties / Costa, E.; Gigante, Giovanni Ettore; Massaro, Enrico; Fiacconi, S.; Piro, L.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 257:2(1987), pp. 429-435. [10.1016/0168-9002(87)90769-8]

Temperature dependence of a BGO-CsI(Tl) phoswich detector properties

GIGANTE, Giovanni Ettore;MASSARO, Enrico;
1987

Abstract

We have studied the variations of the performances, and particularly the discrimination efficiency, of a BGO-CsI(Tl) phoswich detector in the temperature range 2.5–40°C. The scintillation decay time evaluation has been carried out by means of a double constant fraction discriminator and a time to amplitude converter on 1 μs shaped pulses. Good discrimination between BGO and CsI(Tl) events has been obtained over the whole temperature range, even though small efficiency variations are present because of the relative displacement of the acceptance window of the discriminator due to the decay time dependence on temperature. A criterium to minimize this effect, useful in particular for the BGO-CsI(Tl) phoswich, has been developed.
1987
01 Pubblicazione su rivista::01a Articolo in rivista
Temperature dependence of a BGO-CsI(Tl) phoswich detector properties / Costa, E.; Gigante, Giovanni Ettore; Massaro, Enrico; Fiacconi, S.; Piro, L.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 257:2(1987), pp. 429-435. [10.1016/0168-9002(87)90769-8]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/423350
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact