Polysulphone (PS) dosimetry has been a widely used technique for more than 30 years to quantify the erythemally effective UV dose received by anatomic sites (personal exposure). The calibration of PS dosimeters is an important issue as their spectral response is different from the erythemal action spectrum. It is performed exposing a set of PS dosimeters on a horizontal plane and measuring the UV doses received by dosimeters using calibrated spectroradiometers or radiometers. In this study, data collected during PS field campaigns (from 2004 to 2006), using horizontal and differently inclined dosimeters, were analyzed to provide some considerations on the transfer of the horizontal calibration to differently inclined dosimeters, as anatomic sites usually are. The role of sky conditions, of the angle of incidence between the sun and the normal to the slope, and of the type of surrounding surface on the calibration were investigated. It was concluded that PS horizontal calibrations apply to differently inclined dosimeters for incidence angles up to approximately 70 degrees and for surfaces excluding ones with high albedo. Caution should be used in the application of horizontal calibrations for cases of high-incidence angle and/or high albedo surfaces.

Applicability of the polysulphone horizontal calibration to differently inclined dosimeters / Casale, Giuseppe Rocco; Siani, Anna Maria; Diemoz, Henri; Michael G., Kimlin; Colosimo, Alfredo. - In: PHOTOCHEMISTRY AND PHOTOBIOLOGY. - ISSN 0031-8655. - ELETTRONICO. - 88:1(2012), pp. 207-214. [10.1111/j.1751-1097.2011.01006.x]

Applicability of the polysulphone horizontal calibration to differently inclined dosimeters

CASALE, Giuseppe Rocco;SIANI, Anna Maria;DIEMOZ, HENRI;COLOSIMO, Alfredo
2012

Abstract

Polysulphone (PS) dosimetry has been a widely used technique for more than 30 years to quantify the erythemally effective UV dose received by anatomic sites (personal exposure). The calibration of PS dosimeters is an important issue as their spectral response is different from the erythemal action spectrum. It is performed exposing a set of PS dosimeters on a horizontal plane and measuring the UV doses received by dosimeters using calibrated spectroradiometers or radiometers. In this study, data collected during PS field campaigns (from 2004 to 2006), using horizontal and differently inclined dosimeters, were analyzed to provide some considerations on the transfer of the horizontal calibration to differently inclined dosimeters, as anatomic sites usually are. The role of sky conditions, of the angle of incidence between the sun and the normal to the slope, and of the type of surrounding surface on the calibration were investigated. It was concluded that PS horizontal calibrations apply to differently inclined dosimeters for incidence angles up to approximately 70 degrees and for surfaces excluding ones with high albedo. Caution should be used in the application of horizontal calibrations for cases of high-incidence angle and/or high albedo surfaces.
2012
01 Pubblicazione su rivista::01a Articolo in rivista
Applicability of the polysulphone horizontal calibration to differently inclined dosimeters / Casale, Giuseppe Rocco; Siani, Anna Maria; Diemoz, Henri; Michael G., Kimlin; Colosimo, Alfredo. - In: PHOTOCHEMISTRY AND PHOTOBIOLOGY. - ISSN 0031-8655. - ELETTRONICO. - 88:1(2012), pp. 207-214. [10.1111/j.1751-1097.2011.01006.x]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/422084
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 16
social impact