Computer-assisted surgery (CAS) in total knee arthroplasty (TKA) could be useful in reducing the overall blood loss. A prospective randomised study was performed with two groups of 50 patients each of whom were treated for knee arthritis. Patients of group A were treated by a conventional standard procedure, while for patients of group B a specific CAS procedure was used. We determined the intraoperative blood loss according to the Orthopaedic Surgery Transfusion Haemoglobin European Overview (OSTHEO) study. The average blood loss in patients of group A was 1,974 ml (range: 450-3,930 ml) compared to 1,677 ml of patients of group B (range: 500-2,634 ml). A statistically significant difference was found between the two groups (p = 0.0283). Computer-assisted surgery is highly recommended in TKR to save blood. It creates more possibilities to operate on anaemic patients and subjects who cannot accept blood products by reducing blood loss risk.

Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique / Conteduca, Fabio; F., Massai; Iorio, Raffaele; E., Zanzotto; D., Luzon; Ferretti, Andrea. - In: INTERNATIONAL ORTHOPAEDICS. - ISSN 0341-2695. - STAMPA. - 33:6(2009), pp. 1609-1613. [10.1007/s00264-008-0651-7]

Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique

CONTEDUCA, Fabio;IORIO, RAFFAELE;FERRETTI, Andrea
2009

Abstract

Computer-assisted surgery (CAS) in total knee arthroplasty (TKA) could be useful in reducing the overall blood loss. A prospective randomised study was performed with two groups of 50 patients each of whom were treated for knee arthritis. Patients of group A were treated by a conventional standard procedure, while for patients of group B a specific CAS procedure was used. We determined the intraoperative blood loss according to the Orthopaedic Surgery Transfusion Haemoglobin European Overview (OSTHEO) study. The average blood loss in patients of group A was 1,974 ml (range: 450-3,930 ml) compared to 1,677 ml of patients of group B (range: 500-2,634 ml). A statistically significant difference was found between the two groups (p = 0.0283). Computer-assisted surgery is highly recommended in TKR to save blood. It creates more possibilities to operate on anaemic patients and subjects who cannot accept blood products by reducing blood loss risk.
2009
80 and over; aged; arthritis; arthroplasty; blood loss; bone malalignment; computer-assisted; female; humans; knee; knee joint; male; methods; middle aged; prevention /&/ control; prospective studies; replacement; surgery; surgical; treatment outcome
01 Pubblicazione su rivista::01a Articolo in rivista
Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique / Conteduca, Fabio; F., Massai; Iorio, Raffaele; E., Zanzotto; D., Luzon; Ferretti, Andrea. - In: INTERNATIONAL ORTHOPAEDICS. - ISSN 0341-2695. - STAMPA. - 33:6(2009), pp. 1609-1613. [10.1007/s00264-008-0651-7]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/418614
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 49
social impact