The objective of this study was to evaluate the value of a color-coded automated signal intensity curve software package for contrast-enhanced magnetic resonance mammography (CE-MRM) in patients with suspected breast cancer.Thirty-six women with suspected breast cancer based on mammographic and sonographic examinations were preoperatively evaluated on CE-MRM. CE-MRM was performed on a 1.5-T magnet using a 2D Flash dynamic T1-weighted sequence. A dosage of 0.1 mmol/kg of Gd-BOPTA was administered at a flow rate of 2 mL/s followed by 10 mL of saline. Images were analyzed with the new software package and separately with a standard display method. Statistical comparison was performed of the confidence for lesion detection and characterization with the 2 methods and of the diagnostic accuracy for characterization compared with histopathologic findings.At pathology, 54 malignant lesions and 14 benign lesions were evaluated. All 68 (100\%) lesions were detected with both methods and good correlation with histopathologic specimens was obtained. Confidence for both detection and characterization was significantly (P < or = 0.025) better with the color-coded method, although no difference (P > 0.05) between the methods was noted in terms of the sensitivity, specificity, and overall accuracy for lesion characterization. Excellent agreement between the 2 methods was noted for both the determination of lesion size (kappa = 0.77) and determination of SI/T curves (kappa = 0.85).The novel color-coded signal intensity curve software allows lesions to be visualized as false color maps that correspond to conventional signal intensity time curves. Detection and characterization of breast lesions with this method is quick and easily interpretable.

Color-coded automated signal intensity curves for detection and characterization of breast lesions: preliminary evaluation of a new software package for integrated magnetic resonance-based breast imaging / Pediconi, Federica; Catalano, Carlo; F., Venditti; M., Ercolani; L., Carotenuto; S., Padula; E., Moriconi; Roselli, Antonella; Giacomelli, Laura; M. A., Kirchin; Passariello, Roberto. - In: INVESTIGATIVE RADIOLOGY. - ISSN 0020-9996. - STAMPA. - 40:7(2005), pp. 448-457. [10.1097/01.rli.0000167427.33581.f3]

Color-coded automated signal intensity curves for detection and characterization of breast lesions: preliminary evaluation of a new software package for integrated magnetic resonance-based breast imaging.

PEDICONI, FEDERICA;CATALANO, Carlo;ROSELLI, ANTONELLA;GIACOMELLI, Laura;PASSARIELLO, Roberto
2005

Abstract

The objective of this study was to evaluate the value of a color-coded automated signal intensity curve software package for contrast-enhanced magnetic resonance mammography (CE-MRM) in patients with suspected breast cancer.Thirty-six women with suspected breast cancer based on mammographic and sonographic examinations were preoperatively evaluated on CE-MRM. CE-MRM was performed on a 1.5-T magnet using a 2D Flash dynamic T1-weighted sequence. A dosage of 0.1 mmol/kg of Gd-BOPTA was administered at a flow rate of 2 mL/s followed by 10 mL of saline. Images were analyzed with the new software package and separately with a standard display method. Statistical comparison was performed of the confidence for lesion detection and characterization with the 2 methods and of the diagnostic accuracy for characterization compared with histopathologic findings.At pathology, 54 malignant lesions and 14 benign lesions were evaluated. All 68 (100\%) lesions were detected with both methods and good correlation with histopathologic specimens was obtained. Confidence for both detection and characterization was significantly (P < or = 0.025) better with the color-coded method, although no difference (P > 0.05) between the methods was noted in terms of the sensitivity, specificity, and overall accuracy for lesion characterization. Excellent agreement between the 2 methods was noted for both the determination of lesion size (kappa = 0.77) and determination of SI/T curves (kappa = 0.85).The novel color-coded signal intensity curve software allows lesions to be visualized as false color maps that correspond to conventional signal intensity time curves. Detection and characterization of breast lesions with this method is quick and easily interpretable.
2005
Adult; Aged; Breast Neoplasms; diagnosis/pathology/radiography; Color; Contrast Media; Female; Humans; Magnetic Resonance Imaging; instrumentation/methods; Mammography; Middle Aged; Signal Processing; Computer-Assisted; Software
01 Pubblicazione su rivista::01a Articolo in rivista
Color-coded automated signal intensity curves for detection and characterization of breast lesions: preliminary evaluation of a new software package for integrated magnetic resonance-based breast imaging / Pediconi, Federica; Catalano, Carlo; F., Venditti; M., Ercolani; L., Carotenuto; S., Padula; E., Moriconi; Roselli, Antonella; Giacomelli, Laura; M. A., Kirchin; Passariello, Roberto. - In: INVESTIGATIVE RADIOLOGY. - ISSN 0020-9996. - STAMPA. - 40:7(2005), pp. 448-457. [10.1097/01.rli.0000167427.33581.f3]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/415847
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 29
social impact