Repetitive transcranial magnetic stimulation (rTMS) delivered in short trains at 5 Hz frequency and suprathreshold intensity over the primary motor cortex (M1) in healthy subjects facilitates the motor-evoked potential (MEP) amplitude by increasing cortical excitability through mechanisms resembling short-term synaptic plasticity. In this study, to investigate whether rTES acts through similar mechanisms we compared the effects of rTMS and repetitive transcranial electrical stimulation (rTES) (10 stimuli-trains, 5 Hz frequency, suprathreshold intensity) delivered over the M1 on the MEP amplitude. Four healthy subjects were studied in two separate sessions in a relaxed condition. rTMS and anodal rTES were delivered in trains to the left M1 over the motor area for evoking a MEP in the right first dorsal interosseous muscle. Changes in MEP size and latency during the course of the rTMS and rTES trains were compared. The possible effects of muscle activation on MEP amplitude were evaluated. and the possible effects of cutaneous trigeminal fibre activation on corticospinal excitability were excluded in a control experiment testing the MEP amplitude before and after supraorbital nerve repetitive electrical stimulation. Repeated measures analysis of variance (ANOVA) showed that rTES and rTMS trains elicited similar amplitude first MEPs; and a similar magnitude MEP amplitude facilitation during the trains. rTES elicited a first MEP with a shorter latency than rTMS, without significant changes during the course of the train of stimuli. The MEP elicited by single-pulse TES delivered during muscle contraction had a smaller amplitude than the last MEP in the rTES trains. Repetitive supraorbital nerve stimulation left the conditioned MEP unchanged. Our results suggest that 5 Hz-rTES delivered in short trains increases cortical excitability and does so by acting on the excitatory interneurones probably through mechanisms similar to those underlying the rTMS-induced MEP facilitation. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Electrical and magnetic repetitive transcranial stimulation of the primary motor cortex in healthy subjects / Francesca, Gilio; Iacovelli, Elisa; Frasca, Vittorio; Maria, Gabriele; Giacomelli, Elena; DE LENA, Carlo; Anna Maria, Cipriani; Inghilleri, Maurizio. - In: NEUROSCIENCE LETTERS. - ISSN 0304-3940. - 455:1(2009), pp. 1-3. [10.1016/j.neulet.2009.03.035]

Electrical and magnetic repetitive transcranial stimulation of the primary motor cortex in healthy subjects

IACOVELLI, ELISA;FRASCA, VITTORIO;GIACOMELLI, ELENA;DE LENA, Carlo;INGHILLERI, Maurizio
2009

Abstract

Repetitive transcranial magnetic stimulation (rTMS) delivered in short trains at 5 Hz frequency and suprathreshold intensity over the primary motor cortex (M1) in healthy subjects facilitates the motor-evoked potential (MEP) amplitude by increasing cortical excitability through mechanisms resembling short-term synaptic plasticity. In this study, to investigate whether rTES acts through similar mechanisms we compared the effects of rTMS and repetitive transcranial electrical stimulation (rTES) (10 stimuli-trains, 5 Hz frequency, suprathreshold intensity) delivered over the M1 on the MEP amplitude. Four healthy subjects were studied in two separate sessions in a relaxed condition. rTMS and anodal rTES were delivered in trains to the left M1 over the motor area for evoking a MEP in the right first dorsal interosseous muscle. Changes in MEP size and latency during the course of the rTMS and rTES trains were compared. The possible effects of muscle activation on MEP amplitude were evaluated. and the possible effects of cutaneous trigeminal fibre activation on corticospinal excitability were excluded in a control experiment testing the MEP amplitude before and after supraorbital nerve repetitive electrical stimulation. Repeated measures analysis of variance (ANOVA) showed that rTES and rTMS trains elicited similar amplitude first MEPs; and a similar magnitude MEP amplitude facilitation during the trains. rTES elicited a first MEP with a shorter latency than rTMS, without significant changes during the course of the train of stimuli. The MEP elicited by single-pulse TES delivered during muscle contraction had a smaller amplitude than the last MEP in the rTES trains. Repetitive supraorbital nerve stimulation left the conditioned MEP unchanged. Our results suggest that 5 Hz-rTES delivered in short trains increases cortical excitability and does so by acting on the excitatory interneurones probably through mechanisms similar to those underlying the rTMS-induced MEP facilitation. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
2009
cortical excitability; primary motor cortex; repetitive transcranial electric stimulation; repetitive transcranial magnetic stimulation
01 Pubblicazione su rivista::01a Articolo in rivista
Electrical and magnetic repetitive transcranial stimulation of the primary motor cortex in healthy subjects / Francesca, Gilio; Iacovelli, Elisa; Frasca, Vittorio; Maria, Gabriele; Giacomelli, Elena; DE LENA, Carlo; Anna Maria, Cipriani; Inghilleri, Maurizio. - In: NEUROSCIENCE LETTERS. - ISSN 0304-3940. - 455:1(2009), pp. 1-3. [10.1016/j.neulet.2009.03.035]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/406247
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact