Capsular contracture is the most unpredictable complication after mammary augmentation. It presents an uncertain evolution, and is one of the most difficulty complications to treat. Evaluation of this condition usually was relegated to the surgeon's judgment, but currently there are three methods for measuring capsular contracture: palpation, applanation tonometry, and measure of mammary compliance. A prospective study was conducted to evaluate the different methods for managing capsular contracture. Particular attention was paid to the measure mammary compliance with a new device: the Anton Paar Mammacompliance system. This study found a good match between clinical and objective measurements, and also between the measure of applanation tonometry and the measure of mammary compliance. The Anton Paar Mammacompliance system seems to be effective in eliminating the descriptive part and keeping to the measurements and objective data. It is easily reproducible in the various check ups. It permits objective assessment for the measure of capsular contracture.

Mammary compliance: an objective measurement of capsular contracture / Alfano, Carmine; Mazzocchi, M; Scuderi, Nicolo'. - In: AESTHETIC PLASTIC SURGERY. - ISSN 0364-216X. - STAMPA. - 28(2):(2004), pp. 75-79. [10.1007/s00266-004-4005-6]

Mammary compliance: an objective measurement of capsular contracture.

ALFANO, Carmine;SCUDERI, Nicolo'
2004

Abstract

Capsular contracture is the most unpredictable complication after mammary augmentation. It presents an uncertain evolution, and is one of the most difficulty complications to treat. Evaluation of this condition usually was relegated to the surgeon's judgment, but currently there are three methods for measuring capsular contracture: palpation, applanation tonometry, and measure of mammary compliance. A prospective study was conducted to evaluate the different methods for managing capsular contracture. Particular attention was paid to the measure mammary compliance with a new device: the Anton Paar Mammacompliance system. This study found a good match between clinical and objective measurements, and also between the measure of applanation tonometry and the measure of mammary compliance. The Anton Paar Mammacompliance system seems to be effective in eliminating the descriptive part and keeping to the measurements and objective data. It is easily reproducible in the various check ups. It permits objective assessment for the measure of capsular contracture.
2004
APPLANATION TONOMETRY; BREAST
01 Pubblicazione su rivista::01a Articolo in rivista
Mammary compliance: an objective measurement of capsular contracture / Alfano, Carmine; Mazzocchi, M; Scuderi, Nicolo'. - In: AESTHETIC PLASTIC SURGERY. - ISSN 0364-216X. - STAMPA. - 28(2):(2004), pp. 75-79. [10.1007/s00266-004-4005-6]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/4053
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 31
social impact