Computed tomographic images of soft materials are obtained using differential attenuation and transmission method with a tube source of X-rays, for samples like walnut, brew tooth and peaches in order to know the interior properties of the material at optimum energy in terms of attenuation coefficient. At optimum energy it is possible to calculate the three-dimensional representation of inner and outer surfaces of the object. The interior of the soft material is visualized using the novel soft ware in order to know the distribution of attenuation coefficient in terms of density. The results for walnut, brew tooth and peaches are presented as a set of images from the internal parts of the sample.

Computer tomographic images of soft materials using differential attenuation: interior properties of the materials at optimum energy in terms of attenuation coefficient / Rao, D. V.; Cesareo, R.; Brunetti, A.; Takeda, T.; Itai, Y.; Akatsuka, T.; Gigante, Giovanni Ettore. - In: NDT & E INTERNATIONAL. - ISSN 0963-8695. - STAMPA. - 35:8(2002), pp. 573-580. [10.1016/S0963-8695(02)00042-7]

Computer tomographic images of soft materials using differential attenuation: interior properties of the materials at optimum energy in terms of attenuation coefficient

GIGANTE, Giovanni Ettore
2002

Abstract

Computed tomographic images of soft materials are obtained using differential attenuation and transmission method with a tube source of X-rays, for samples like walnut, brew tooth and peaches in order to know the interior properties of the material at optimum energy in terms of attenuation coefficient. At optimum energy it is possible to calculate the three-dimensional representation of inner and outer surfaces of the object. The interior of the soft material is visualized using the novel soft ware in order to know the distribution of attenuation coefficient in terms of density. The results for walnut, brew tooth and peaches are presented as a set of images from the internal parts of the sample.
2002
Images; Soft materials; Transmission and differential attenuation; Optimum energy; Monochromacy; Solid angle; Geometrical efficiency; Imaging techniques
01 Pubblicazione su rivista::01a Articolo in rivista
Computer tomographic images of soft materials using differential attenuation: interior properties of the materials at optimum energy in terms of attenuation coefficient / Rao, D. V.; Cesareo, R.; Brunetti, A.; Takeda, T.; Itai, Y.; Akatsuka, T.; Gigante, Giovanni Ettore. - In: NDT & E INTERNATIONAL. - ISSN 0963-8695. - STAMPA. - 35:8(2002), pp. 573-580. [10.1016/S0963-8695(02)00042-7]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/402452
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact