A Monte Carlo simulation of a 50 mm x 50 mm x 4 mm continuous crystal has been developed to investigate the correlation between the scintillation light width (sigma) and the Depth of Interaction (DoI) within the crystal. Our studies are based on a LaBr(3)(Ce) crystal, in order to take advantage of its high light yield to reduce the statistic uncertainties on the estimators of the sigma. The first one, the standard deviation of the light distribution, has demonstrated a poor, though linear, correlation to DoI, that is not experimentally detectable. Otherwise, the second estimator, N/I, is the ratio of the total number of photoelectrons to the maximum number of photoelectrons collected from a single anode, in a scintillation event. N/I has been found to have the best correlation to DoI, that provides 2 mm resolution.

DoI position resolution in a continuous LaBr3(Ce) scintillation crystal for γ-ray imaging / Pani, Roberto; Nourbakhsh, Shervin; P., Pani; P., Bennati; Pellegrini, Rosanna; Cinti, Maria Nerina; R., Scafe; B., Cassano; F., Navarria; S., Lo Meo; N., Lanconelli; G., Moschini; P., Boccaccio; Fabbria, ; A., Fabbri; V. O., Cencelli; Francesco De, Notaristefani. - In: NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS. - ISSN 0920-5632. - STAMPA. - 215:1(2011), pp. 324-327. (Intervento presentato al convegno 12th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD 10) tenutosi a Siena, ITALY nel JUN 07-10, 2010) [10.1016/j.nuclphysbps.2011.04.044].

DoI position resolution in a continuous LaBr3(Ce) scintillation crystal for γ-ray imaging

PANI, Roberto;NOURBAKHSH, SHERVIN;PELLEGRINI, Rosanna;CINTI, Maria Nerina;
2011

Abstract

A Monte Carlo simulation of a 50 mm x 50 mm x 4 mm continuous crystal has been developed to investigate the correlation between the scintillation light width (sigma) and the Depth of Interaction (DoI) within the crystal. Our studies are based on a LaBr(3)(Ce) crystal, in order to take advantage of its high light yield to reduce the statistic uncertainties on the estimators of the sigma. The first one, the standard deviation of the light distribution, has demonstrated a poor, though linear, correlation to DoI, that is not experimentally detectable. Otherwise, the second estimator, N/I, is the ratio of the total number of photoelectrons to the maximum number of photoelectrons collected from a single anode, in a scintillation event. N/I has been found to have the best correlation to DoI, that provides 2 mm resolution.
2011
01 Pubblicazione su rivista::01a Articolo in rivista
DoI position resolution in a continuous LaBr3(Ce) scintillation crystal for γ-ray imaging / Pani, Roberto; Nourbakhsh, Shervin; P., Pani; P., Bennati; Pellegrini, Rosanna; Cinti, Maria Nerina; R., Scafe; B., Cassano; F., Navarria; S., Lo Meo; N., Lanconelli; G., Moschini; P., Boccaccio; Fabbria, ; A., Fabbri; V. O., Cencelli; Francesco De, Notaristefani. - In: NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS. - ISSN 0920-5632. - STAMPA. - 215:1(2011), pp. 324-327. (Intervento presentato al convegno 12th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD 10) tenutosi a Siena, ITALY nel JUN 07-10, 2010) [10.1016/j.nuclphysbps.2011.04.044].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/400892
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact