Twenty collections of peripheral blood stem cells were performed in 3 patients (2 NHL, 1 AML) using the Haemonetics V50S discontinuous flow blood cell separator. A modified lymphocyte collection protocol (Nebraska Surge) was used in all instances. Leukapheresis were performed after 1 or 2 courses of chemotherapy and started when peripheral blood leukocytes count reached 1 x 10e9/l and platelets count 80 x 10e9/l. A mean blood volume of 5.9 +/- 0.6 litres was processed per procedure and the mean yields for mononuclear cells, nucleated cells and CFU-GM were respectively 5.4 +/- 1.4 x 10e9, 4.9 +/- 1.6 x 10e9 and 128.5 +/- 182.3 x 10e4 per procedure. Haemonetics V50S had showed a mean collection efficiency for mononuclear cells of 67.5 +/- 5.0\% per procedure. Results obtained are not significantly different from the ones obtained with an automated continuous flow separator even if extracorporeal circulation is consistently high in patients with a low hematocrit when the 250 ml Latham Bowl is used.

Collection of peripheral blood stem cells using an automated discontinuous flow blood cell separator / Pierelli, Luca; G., Menichella; A., Paoloni; L., Teofili; S., Sica; M. L., Foddai; P. L., Rossi; G., Leone; G., Mango; B., Bizzi. - In: HAEMATOLOGICA. - ISSN 0390-6078. - 75 Suppl 1:(1990), pp. 29-32.

Collection of peripheral blood stem cells using an automated discontinuous flow blood cell separator.

PIERELLI, LUCA;
1990

Abstract

Twenty collections of peripheral blood stem cells were performed in 3 patients (2 NHL, 1 AML) using the Haemonetics V50S discontinuous flow blood cell separator. A modified lymphocyte collection protocol (Nebraska Surge) was used in all instances. Leukapheresis were performed after 1 or 2 courses of chemotherapy and started when peripheral blood leukocytes count reached 1 x 10e9/l and platelets count 80 x 10e9/l. A mean blood volume of 5.9 +/- 0.6 litres was processed per procedure and the mean yields for mononuclear cells, nucleated cells and CFU-GM were respectively 5.4 +/- 1.4 x 10e9, 4.9 +/- 1.6 x 10e9 and 128.5 +/- 182.3 x 10e4 per procedure. Haemonetics V50S had showed a mean collection efficiency for mononuclear cells of 67.5 +/- 5.0\% per procedure. Results obtained are not significantly different from the ones obtained with an automated continuous flow separator even if extracorporeal circulation is consistently high in patients with a low hematocrit when the 250 ml Latham Bowl is used.
1990
Cell Separation; instrumentation; Hematopoietic Stem Cells; cytology; Humans; Leukapheresis
01 Pubblicazione su rivista::01a Articolo in rivista
Collection of peripheral blood stem cells using an automated discontinuous flow blood cell separator / Pierelli, Luca; G., Menichella; A., Paoloni; L., Teofili; S., Sica; M. L., Foddai; P. L., Rossi; G., Leone; G., Mango; B., Bizzi. - In: HAEMATOLOGICA. - ISSN 0390-6078. - 75 Suppl 1:(1990), pp. 29-32.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/399342
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 7
social impact