In older to assess specificity and sensitivity of the prone scintimammography (PSM) in a large series with 99m-Tc MIBI, we performed a three-center study; 420 patients were studied: after mammography all the patients were submitted to PSM and biopsy and/or operation. PSM was considered positive if hot spot within the breast was observed. In palpable masses sensitivity was 0.98 and specificity 0.89, non palpable masses showed a sensitivity of 0.62 and a specificity of 0.91. When the cancers were stratified for T category the sensitivity was 0.28 in T-1s, 0.26 in the group of T-1a carcinomas, 0.56 in T-1b, 0.95 in T-1c, and 0.97 T-2 tumors. Physical factors such as attenuation, Compton scattering from chest, as well as biological factors have a role in breast tumor imaging. In the tumors smaller than 1cm biological factors are probably involved too.

A three center study on the diagnostic accuracy of 99mTc-MIBI scintimammography / Scopinaro, Francesco; O., Schillaci; W., Ussof; K., Nordling; R., Capoferro; DE VINCENTIS, Giuseppe; R., Danieli; M., Ierardi; V., Picardi; R., Tavolaro; CENTI COLELLA, Antonio. - In: ANTICANCER RESEARCH. - ISSN 0250-7005. - 17:3 B(1997), pp. 1631-1634.

A three center study on the diagnostic accuracy of 99mTc-MIBI scintimammography

SCOPINARO, Francesco;DE VINCENTIS, Giuseppe;CENTI COLELLA, Antonio
1997

Abstract

In older to assess specificity and sensitivity of the prone scintimammography (PSM) in a large series with 99m-Tc MIBI, we performed a three-center study; 420 patients were studied: after mammography all the patients were submitted to PSM and biopsy and/or operation. PSM was considered positive if hot spot within the breast was observed. In palpable masses sensitivity was 0.98 and specificity 0.89, non palpable masses showed a sensitivity of 0.62 and a specificity of 0.91. When the cancers were stratified for T category the sensitivity was 0.28 in T-1s, 0.26 in the group of T-1a carcinomas, 0.56 in T-1b, 0.95 in T-1c, and 0.97 T-2 tumors. Physical factors such as attenuation, Compton scattering from chest, as well as biological factors have a role in breast tumor imaging. In the tumors smaller than 1cm biological factors are probably involved too.
1997
breast cancer; diagnostic accuracy; sestamibi; tumor size
01 Pubblicazione su rivista::01a Articolo in rivista
A three center study on the diagnostic accuracy of 99mTc-MIBI scintimammography / Scopinaro, Francesco; O., Schillaci; W., Ussof; K., Nordling; R., Capoferro; DE VINCENTIS, Giuseppe; R., Danieli; M., Ierardi; V., Picardi; R., Tavolaro; CENTI COLELLA, Antonio. - In: ANTICANCER RESEARCH. - ISSN 0250-7005. - 17:3 B(1997), pp. 1631-1634.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/395210
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 104
  • ???jsp.display-item.citation.isi??? 85
social impact