The fluorescence spectra from rat bones of different age groups (8, 56 and 78 weeks) and lumber vertebra were measured with 8, 10 and 12 keV synchrotron X-rays. We have utilized the new hard X-ray micro-spectroscopy beamline facility, X27A, available at NSLS with a primary beam spot size of the order of similar to 10 mu m. With this spatial resolution and high flux throughput, X-ray fluorescent intensities for Ca and other trace elements were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. Regarding the lumber vertebra, we acquired the fluorescence spectra from the left, right and middle portions and calcium accumulation was evaluated and compared with the other samples. We have identified the major trace elements of Ca, Ni, Fe and Zn and minor trace elements of Ti, Cr and Mn in the sample. The percentage of scattered radiation and trace element contributions from these samples were highlighted at different energies. (C) 2008 Elsevier B.V. All rights reserved.

Synchrotron-induced X-ray fluorescence from rat bone and lumber vertebra of different age groups / Donepudi V., Rao; Medasani, Swapna; Roberto, Cesareo; Antonio, Brunetti; Tako, Akatsuka; Tetsuya, Yuasa; Tohoru, Takeda; Giuliana, Tromba; Gigante, Giovanni Ettore. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - STAMPA. - 267:3(2009), pp. 502-505. [10.1016/j.nimb.2008.11.013]

Synchrotron-induced X-ray fluorescence from rat bone and lumber vertebra of different age groups

GIGANTE, Giovanni Ettore
2009

Abstract

The fluorescence spectra from rat bones of different age groups (8, 56 and 78 weeks) and lumber vertebra were measured with 8, 10 and 12 keV synchrotron X-rays. We have utilized the new hard X-ray micro-spectroscopy beamline facility, X27A, available at NSLS with a primary beam spot size of the order of similar to 10 mu m. With this spatial resolution and high flux throughput, X-ray fluorescent intensities for Ca and other trace elements were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. Regarding the lumber vertebra, we acquired the fluorescence spectra from the left, right and middle portions and calcium accumulation was evaluated and compared with the other samples. We have identified the major trace elements of Ca, Ni, Fe and Zn and minor trace elements of Ti, Cr and Mn in the sample. The percentage of scattered radiation and trace element contributions from these samples were highlighted at different energies. (C) 2008 Elsevier B.V. All rights reserved.
2009
different age groups; fluorescence; lumber vertebra; rat bone; synchrotron; trace elements
01 Pubblicazione su rivista::01a Articolo in rivista
Synchrotron-induced X-ray fluorescence from rat bone and lumber vertebra of different age groups / Donepudi V., Rao; Medasani, Swapna; Roberto, Cesareo; Antonio, Brunetti; Tako, Akatsuka; Tetsuya, Yuasa; Tohoru, Takeda; Giuliana, Tromba; Gigante, Giovanni Ettore. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - STAMPA. - 267:3(2009), pp. 502-505. [10.1016/j.nimb.2008.11.013]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/393239
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact