A fourth generation amine-terminated dendrimer (G4-PAMAM) was chemically functionalized through ferrocene (Fc) tethered groups (length of tether = C 11), The electrochemical properties of the new dendrimer molecule immobilized by using polyazetidine prepolymer (PAP) onto multi-walled carbon nanotubes (MWCNTs) screen printed electrode (SPE) surface, have been evaluated; then the Fc modified SPE was coupled to glucose oxidase (GOx) for the development of a reagentless glucose biosensor. The analytical performances of this device has been studied providing a linear response for one decade in the range 0.7-7.0 mM glucose with an RSD always below 4 %. © The Electrochemical Society.

Study of ferrocene-modified G4-PAMAM dendrimer for reagentless biosensor development / D'Annibale, Andrea; Deriu, Daniela; Favero, Gabriele; Mazzei, Franco. - In: ECS TRANSACTIONS. - ISSN 1938-5862. - STAMPA. - 16:11(2008), pp. 105-113. (Intervento presentato al convegno Chemical Sensors 8: Chemical (Gas, Ion, Bio) Sensors and Analytical Systems - 214th ECS Meeting tenutosi a Honolulu, HI nel 12 October 2008 through 17 October 2008) [10.1149/1.2981110].

Study of ferrocene-modified G4-PAMAM dendrimer for reagentless biosensor development

D'ANNIBALE, Andrea;DERIU, Daniela;FAVERO, Gabriele;MAZZEI, Franco
2008

Abstract

A fourth generation amine-terminated dendrimer (G4-PAMAM) was chemically functionalized through ferrocene (Fc) tethered groups (length of tether = C 11), The electrochemical properties of the new dendrimer molecule immobilized by using polyazetidine prepolymer (PAP) onto multi-walled carbon nanotubes (MWCNTs) screen printed electrode (SPE) surface, have been evaluated; then the Fc modified SPE was coupled to glucose oxidase (GOx) for the development of a reagentless glucose biosensor. The analytical performances of this device has been studied providing a linear response for one decade in the range 0.7-7.0 mM glucose with an RSD always below 4 %. © The Electrochemical Society.
2008
Chemical Sensors 8: Chemical (Gas, Ion, Bio) Sensors and Analytical Systems - 214th ECS Meeting
04 Pubblicazione in atti di convegno::04c Atto di convegno in rivista
Study of ferrocene-modified G4-PAMAM dendrimer for reagentless biosensor development / D'Annibale, Andrea; Deriu, Daniela; Favero, Gabriele; Mazzei, Franco. - In: ECS TRANSACTIONS. - ISSN 1938-5862. - STAMPA. - 16:11(2008), pp. 105-113. (Intervento presentato al convegno Chemical Sensors 8: Chemical (Gas, Ion, Bio) Sensors and Analytical Systems - 214th ECS Meeting tenutosi a Honolulu, HI nel 12 October 2008 through 17 October 2008) [10.1149/1.2981110].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/388433
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
social impact