In this work we report on a system for food quality analysis based on the use of a "smart" thin layer chromatography plate, which couples an amorphous silicon photosensor array to a chromatographic plate. The system is able to give quantitative information by measuring the fluorescence of the analyte during the chromatographic run. In particular, the system has been tested to detect and quantify aflatoxins B 1, B 2, G 1 and G 2. The aflatoxin quantity is proportional to the photocurrent flowing in the p-i-n amorphous silicon diode junction, as the effect of the analyte fluorescence excited by a 365 nm UV radiation. Characterization performed diluting 5-20 ng of aflatoxin in 2 μl of methanol demonstrate the capability of the system to detect in real time the analyte separation and to quantify the toxin. Copyright © 2010 American Scientific Publishers All rights reserved.

Linear Photosensor Array for On-Chip Food Quality Control Based on Thin Layer Chromatography / Caputo, Domenico; DE CESARE, Giampiero; Fanelli, Corrado; Manetti, Cesare; Nascetti, Augusto; A., Ricelli; Scipinotti, Riccardo. - In: SENSOR LETTERS. - ISSN 1546-198X. - STAMPA. - 8:3(2010), pp. 465-469. (Intervento presentato al convegno Spring Meeting of the European-Materials-Research-Society tenutosi a Strasbourg, FRANCE nel JUN 08-12, 2009) [10.1166/sl.2010.1295].

Linear Photosensor Array for On-Chip Food Quality Control Based on Thin Layer Chromatography

CAPUTO, Domenico;DE CESARE, Giampiero;FANELLI, Corrado;MANETTI, Cesare;NASCETTI, Augusto;SCIPINOTTI, RICCARDO
2010

Abstract

In this work we report on a system for food quality analysis based on the use of a "smart" thin layer chromatography plate, which couples an amorphous silicon photosensor array to a chromatographic plate. The system is able to give quantitative information by measuring the fluorescence of the analyte during the chromatographic run. In particular, the system has been tested to detect and quantify aflatoxins B 1, B 2, G 1 and G 2. The aflatoxin quantity is proportional to the photocurrent flowing in the p-i-n amorphous silicon diode junction, as the effect of the analyte fluorescence excited by a 365 nm UV radiation. Characterization performed diluting 5-20 ng of aflatoxin in 2 μl of methanol demonstrate the capability of the system to detect in real time the analyte separation and to quantify the toxin. Copyright © 2010 American Scientific Publishers All rights reserved.
2010
Spring Meeting of the European-Materials-Research-Society
thin layer chromatography; food quality control; aflatoxin; amorphous silicon
04 Pubblicazione in atti di convegno::04c Atto di convegno in rivista
Linear Photosensor Array for On-Chip Food Quality Control Based on Thin Layer Chromatography / Caputo, Domenico; DE CESARE, Giampiero; Fanelli, Corrado; Manetti, Cesare; Nascetti, Augusto; A., Ricelli; Scipinotti, Riccardo. - In: SENSOR LETTERS. - ISSN 1546-198X. - STAMPA. - 8:3(2010), pp. 465-469. (Intervento presentato al convegno Spring Meeting of the European-Materials-Research-Society tenutosi a Strasbourg, FRANCE nel JUN 08-12, 2009) [10.1166/sl.2010.1295].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/387736
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact