Magnetic Resonance Angiography (MRA) is becoming an accurate technique to study vascular conditions, especially when the intracranial circulation is involved. Nevertheless, the contrast-to-noise (C/N) ratio in MRA images is often inadequate to obtain diagnostic images. C/N ratio can be increased by using magnetization transfer contrast (MTC), the technique which allows to reduce the signal from the stationary tissues surrounding vascular structures. To demonstrate the value of MTC, 10 healthy volunteers and 10 patients with different cerebral vascular conditions were examined. All exams were performed using 3D MOTSA (Multiple Overlapping Thin Slab Acquisition) Time of Flight sequences, with and without MTC. A quantitative analysis was carried out in the images with and without MTC, measuring the signal intensity value in the regions of interest at the vascular and stationary structures. A qualitative analysis was also carried out with a double blind study by two independent radiologists. Our results showed that MTC allows to reduce stationary tissues signal intensity, without affecting flowing blood signal intensity. Therefore, the C/N ratio is increased, thus allowing better depiction of smaller peripheral branches. In conclusion, MTC applied to intracranial MRA allows image quality to be markedly improved, with an overall increase in the diagnostic accuracy of this technique.

[Magnetic resonance angiography of the intracranial circle using magnetization transfer contrast (MTC)] / Catalano, Carlo; P., Pavone; Laghi, Andrea; J., Faroni; M., Clementi; M., Di Girolamo; G. A., Petroni; Passariello, Roberto. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 89:3(1995), pp. 245-249.

[Magnetic resonance angiography of the intracranial circle using magnetization transfer contrast (MTC)].

CATALANO, Carlo;LAGHI, ANDREA;PASSARIELLO, Roberto
1995

Abstract

Magnetic Resonance Angiography (MRA) is becoming an accurate technique to study vascular conditions, especially when the intracranial circulation is involved. Nevertheless, the contrast-to-noise (C/N) ratio in MRA images is often inadequate to obtain diagnostic images. C/N ratio can be increased by using magnetization transfer contrast (MTC), the technique which allows to reduce the signal from the stationary tissues surrounding vascular structures. To demonstrate the value of MTC, 10 healthy volunteers and 10 patients with different cerebral vascular conditions were examined. All exams were performed using 3D MOTSA (Multiple Overlapping Thin Slab Acquisition) Time of Flight sequences, with and without MTC. A quantitative analysis was carried out in the images with and without MTC, measuring the signal intensity value in the regions of interest at the vascular and stationary structures. A qualitative analysis was also carried out with a double blind study by two independent radiologists. Our results showed that MTC allows to reduce stationary tissues signal intensity, without affecting flowing blood signal intensity. Therefore, the C/N ratio is increased, thus allowing better depiction of smaller peripheral branches. In conclusion, MTC applied to intracranial MRA allows image quality to be markedly improved, with an overall increase in the diagnostic accuracy of this technique.
1995
cerebrovascular circulation; cerebrovascular disorders; evaluation studies as topic; humans; intracranial aneurysm; intracranial arteriovenous malformations; magnetic resonance angiography
01 Pubblicazione su rivista::01a Articolo in rivista
[Magnetic resonance angiography of the intracranial circle using magnetization transfer contrast (MTC)] / Catalano, Carlo; P., Pavone; Laghi, Andrea; J., Faroni; M., Clementi; M., Di Girolamo; G. A., Petroni; Passariello, Roberto. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 89:3(1995), pp. 245-249.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/387094
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact