The aim of this study was to assess the accuracy of translucency rendering (TR) in computed tomographic (CT) colonography without cathartic preparation using primary 3D reading. From 350 patients with 482 endoscopically verified polyps, 50 pathologically proven polyps and 50 pseudopolyps were retrospectively examined. For faecal tagging, all patients ingested 140 ml of orally administered iodinated contrast agent (diatrizoate meglumine and diatrizoate sodium) at meals 48 h prior to CT colonography examination and two h prior to scanning. CT colonography was performed using a 64-section CT scanner. Colonoscopy with segmental unblinding was performed within 2 weeks after CT. Three independent radiologists retrospectively evaluated TRCT clonographic images using a dedicated software package (V3D-Colon System). To enable size-dependent statistical analysis, lesions were stratified into the following size categories: small (a parts per thousand currency sign5 mm), intermediate (6-9 mm), and large (a parts per thousand yen10 mm). Overall average TR sensitivity for polyp characterisation was 96.6%, and overall average specificity for pseudopolyp characterisation was 91.3%. Overall average diagnostic accuracy (area under the curve) of TR for characterising colonic lesions was 0.97. TR is an accurate tool that facilitates interpretation of images obtained with a primary 3D analysis, thus enabling easy differentiation of polyps from pseudopolyps.

Diagnostic accuracy of translucency rendering to differentiate polyps from pseudopolyps at 3D endoluminal CT colonography: a feasibility study / Guerrisi, Antonino; Marin, Daniele; Laghi, Andrea; Di Martino, M.; Franco, Iafrate; Riccardo, Iannaccone; Catalano, Carlo; Passariello, Roberto. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 115:5(2010), pp. 758-770. [10.1007/s11547-010-0538-8]

Diagnostic accuracy of translucency rendering to differentiate polyps from pseudopolyps at 3D endoluminal CT colonography: a feasibility study

GUERRISI, ANTONINO;MARIN, DANIELE;LAGHI, ANDREA;M. Di Martino;CATALANO, Carlo;PASSARIELLO, Roberto
2010

Abstract

The aim of this study was to assess the accuracy of translucency rendering (TR) in computed tomographic (CT) colonography without cathartic preparation using primary 3D reading. From 350 patients with 482 endoscopically verified polyps, 50 pathologically proven polyps and 50 pseudopolyps were retrospectively examined. For faecal tagging, all patients ingested 140 ml of orally administered iodinated contrast agent (diatrizoate meglumine and diatrizoate sodium) at meals 48 h prior to CT colonography examination and two h prior to scanning. CT colonography was performed using a 64-section CT scanner. Colonoscopy with segmental unblinding was performed within 2 weeks after CT. Three independent radiologists retrospectively evaluated TRCT clonographic images using a dedicated software package (V3D-Colon System). To enable size-dependent statistical analysis, lesions were stratified into the following size categories: small (a parts per thousand currency sign5 mm), intermediate (6-9 mm), and large (a parts per thousand yen10 mm). Overall average TR sensitivity for polyp characterisation was 96.6%, and overall average specificity for pseudopolyp characterisation was 91.3%. Overall average diagnostic accuracy (area under the curve) of TR for characterising colonic lesions was 0.97. TR is an accurate tool that facilitates interpretation of images obtained with a primary 3D analysis, thus enabling easy differentiation of polyps from pseudopolyps.
2010
radiographic image enhancement; imaging: three-dimensional; contrast media; middle aged; adult; aged: 80 and over; area under curve; humans; sensitivity and specificity; translucency rendering; colonoscopy; aged; diagnosis: differential; three-dimensional (3d) analysis; software; colonic polyps; diatrizoate; radiographic image interpretation: computer-assisted; ct colonography; colonography: computed tomographic; retrospective studies
01 Pubblicazione su rivista::01a Articolo in rivista
Diagnostic accuracy of translucency rendering to differentiate polyps from pseudopolyps at 3D endoluminal CT colonography: a feasibility study / Guerrisi, Antonino; Marin, Daniele; Laghi, Andrea; Di Martino, M.; Franco, Iafrate; Riccardo, Iannaccone; Catalano, Carlo; Passariello, Roberto. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 115:5(2010), pp. 758-770. [10.1007/s11547-010-0538-8]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/386952
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact