An experimental apparatus has been built in order to perform sensitivity analysis on the performance of a natural draft-dry cooling tower. This component plays an important role in the passive system for the residual heat decay removal foreseen in the MARS reactor and in the GCFR of the Generation IV reactors. The sensitivity analysis has investigated: 1) the heat exchanger arrangement; two different arrangements have been considered: a horizontal arrangement, in which a system of electrical heaters are placed at the inlet cross section of the tower, and a vertical arrangement, with the heaters distributed vertically around the circumference of the tower. 2) The shape of the cooling tower; by varying the angle of the shell inclination it is possible to obtain a different shape for the tower itself. An upper and a lower angle inclination were modified and by a calculation procedure eleven different configuration were selected. 3) The effect of cross wind on the tower performance. An equation-based procedure to design the dry-cooling tower is presented. In order to evaluate the influence of the shape and the heat exchanger arrangement on the performance of the cooling tower, a geometrical factor (FG) and a thermal factor (FT) are introduced. By analyzing the experimental results, engineering design relations are obtained to model the cooling tower performance. The comparison between the experimental heat transfer coefficient and the heat transfer coefficient obtained by the mathematical procedure shows that there is a good agreement. The influence of wind has been investigated on selected configurations and it has been studied by introducing several coefficients for the comparison: a wind effect and a pressure coefficients were used to evaluate the effect at the throat; a power coefficient, a mean static and mean dynamic pressure coefficients were also defined in order to compare the influence of the wind on different configurations. The obtained results show that it is possible to evaluate the shape and the heat exchanger arrangement to optimize the performance of the cooling tower either in windless condition either in presence of cross wind.

An experimental study on natural draft-dry cooling tower as part of the passive system for the residual decay heat removal / Caruso, Gianfranco; M., Fatone; Naviglio, Antonio. - STAMPA. - 2:(2008), pp. 773-782. (Intervento presentato al convegno International Congress on Advances in Nuclear Power Plants - ICAPP 2007, "The Nuclear Renaissance at Work" tenutosi a Nice nel 13-18/05/2007).

An experimental study on natural draft-dry cooling tower as part of the passive system for the residual decay heat removal

CARUSO, Gianfranco;NAVIGLIO, Antonio
2008

Abstract

An experimental apparatus has been built in order to perform sensitivity analysis on the performance of a natural draft-dry cooling tower. This component plays an important role in the passive system for the residual heat decay removal foreseen in the MARS reactor and in the GCFR of the Generation IV reactors. The sensitivity analysis has investigated: 1) the heat exchanger arrangement; two different arrangements have been considered: a horizontal arrangement, in which a system of electrical heaters are placed at the inlet cross section of the tower, and a vertical arrangement, with the heaters distributed vertically around the circumference of the tower. 2) The shape of the cooling tower; by varying the angle of the shell inclination it is possible to obtain a different shape for the tower itself. An upper and a lower angle inclination were modified and by a calculation procedure eleven different configuration were selected. 3) The effect of cross wind on the tower performance. An equation-based procedure to design the dry-cooling tower is presented. In order to evaluate the influence of the shape and the heat exchanger arrangement on the performance of the cooling tower, a geometrical factor (FG) and a thermal factor (FT) are introduced. By analyzing the experimental results, engineering design relations are obtained to model the cooling tower performance. The comparison between the experimental heat transfer coefficient and the heat transfer coefficient obtained by the mathematical procedure shows that there is a good agreement. The influence of wind has been investigated on selected configurations and it has been studied by introducing several coefficients for the comparison: a wind effect and a pressure coefficients were used to evaluate the effect at the throat; a power coefficient, a mean static and mean dynamic pressure coefficients were also defined in order to compare the influence of the wind on different configurations. The obtained results show that it is possible to evaluate the shape and the heat exchanger arrangement to optimize the performance of the cooling tower either in windless condition either in presence of cross wind.
2008
International Congress on Advances in Nuclear Power Plants - ICAPP 2007, "The Nuclear Renaissance at Work"
COOLING TOWERS; NUCLEAR ENERGY
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
An experimental study on natural draft-dry cooling tower as part of the passive system for the residual decay heat removal / Caruso, Gianfranco; M., Fatone; Naviglio, Antonio. - STAMPA. - 2:(2008), pp. 773-782. (Intervento presentato al convegno International Congress on Advances in Nuclear Power Plants - ICAPP 2007, "The Nuclear Renaissance at Work" tenutosi a Nice nel 13-18/05/2007).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/381120
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact