In recent years the use of devices called Heat and Moisture Exchangers (HME) has become widespread as gas conditioners for ICU patients requiring mechanical ventilation. As an important variation of the resistive properties of the HME, related to flow and duration of use, has recently been pointed out during 'in vitro' studies, the use of these devices in COPD patients could increase the levels of auto PEEP and dynamic hyperinflation. In this study we have compared the levels of auto PEEP and difference in functional residual capacity (Δ FRC) in a group of COPD patients, requiring controlled mechanical ventilation (CMV), at basal conditions and after the insertion into the circuit of three HMEs (Dar Hygrobac, Pall Ultipor, Engstrom Edith) at random: the results obtained excluded a significant increase of auto PEEP and Δ (FRC) both with 'new' HMEs and after 12 h of continuous use.

EFFECTS OF THE HEAT-MOISTURE EXCHANGERS ON DYNAMIC HYPERINFLATION OF MECHANICALLY VENTILATED COPD PATIENTS / G., Conti; DE BLASI, Roberto Alberto; Rocco, Monica; P., Pelaia; M., Antonelli; Bufi, Maurizio; Mattia, Consalvo; A., Gasparetto. - In: INTENSIVE CARE MEDICINE. - ISSN 0342-4642. - STAMPA. - 16:7(1990), pp. 441-443. [10.1007/bf01711222]

EFFECTS OF THE HEAT-MOISTURE EXCHANGERS ON DYNAMIC HYPERINFLATION OF MECHANICALLY VENTILATED COPD PATIENTS

DE BLASI, Roberto Alberto;ROCCO, Monica;BUFI, Maurizio;MATTIA, Consalvo;
1990

Abstract

In recent years the use of devices called Heat and Moisture Exchangers (HME) has become widespread as gas conditioners for ICU patients requiring mechanical ventilation. As an important variation of the resistive properties of the HME, related to flow and duration of use, has recently been pointed out during 'in vitro' studies, the use of these devices in COPD patients could increase the levels of auto PEEP and dynamic hyperinflation. In this study we have compared the levels of auto PEEP and difference in functional residual capacity (Δ FRC) in a group of COPD patients, requiring controlled mechanical ventilation (CMV), at basal conditions and after the insertion into the circuit of three HMEs (Dar Hygrobac, Pall Ultipor, Engstrom Edith) at random: the results obtained excluded a significant increase of auto PEEP and Δ (FRC) both with 'new' HMEs and after 12 h of continuous use.
1990
chronic obstructive pulmonary disease
01 Pubblicazione su rivista::01a Articolo in rivista
EFFECTS OF THE HEAT-MOISTURE EXCHANGERS ON DYNAMIC HYPERINFLATION OF MECHANICALLY VENTILATED COPD PATIENTS / G., Conti; DE BLASI, Roberto Alberto; Rocco, Monica; P., Pelaia; M., Antonelli; Bufi, Maurizio; Mattia, Consalvo; A., Gasparetto. - In: INTENSIVE CARE MEDICINE. - ISSN 0342-4642. - STAMPA. - 16:7(1990), pp. 441-443. [10.1007/bf01711222]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/376541
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 29
social impact