The work focused on the analysis of the connection between a photovoltaic (PV) plant and an electrolyzer for hydrogen production. On the basis of PV plant and electrolyzer experimental data, the effectiveness of the models adopted in the simulation program has been verified in order to choose the best model and, eventually, modify some parameters. By running the simulations, the procedure to optimize the PV plant and the electrolyzer combination has been established. In fact, the simulation results might be considered to size an electrolyzer as small as possible, which is able to exploit up to the maximum power actually produced by the PV plant during a working year. This criterion allows minimizing the overall plant costs. Furthermore, the possibility of deleting the Maximum Power Point Tracker (MPPT) and the DC/DC converter has been analyzed. On the basis of the obtained results, this opportunity is preferable to avoid the energy losses in the power control system; and it is convenient even from an economic point of view, considering that the electronic devices costs are comparable with the PV plant ones.

PV-Electrolyzer plant: models and optimization procedure / P., Artuso; F., Zuccari; Dell'Era, Alessandro; F., Orecchini. - In: JOURNAL OF SOLAR ENERGY ENGINEERING. - ISSN 0199-6231. - ELETTRONICO. - 132:(2010), pp. 1-10. (Intervento presentato al convegno 3rd International Conference on Energy Sustainability tenutosi a San Francisco, CA nel JUL 19-23, 2009) [10.1115/1.4001673].

PV-Electrolyzer plant: models and optimization procedure

DELL'ERA, Alessandro;
2010

Abstract

The work focused on the analysis of the connection between a photovoltaic (PV) plant and an electrolyzer for hydrogen production. On the basis of PV plant and electrolyzer experimental data, the effectiveness of the models adopted in the simulation program has been verified in order to choose the best model and, eventually, modify some parameters. By running the simulations, the procedure to optimize the PV plant and the electrolyzer combination has been established. In fact, the simulation results might be considered to size an electrolyzer as small as possible, which is able to exploit up to the maximum power actually produced by the PV plant during a working year. This criterion allows minimizing the overall plant costs. Furthermore, the possibility of deleting the Maximum Power Point Tracker (MPPT) and the DC/DC converter has been analyzed. On the basis of the obtained results, this opportunity is preferable to avoid the energy losses in the power control system; and it is convenient even from an economic point of view, considering that the electronic devices costs are comparable with the PV plant ones.
2010
Operational Experience; Renewable Energy; Supply-System
01 Pubblicazione su rivista::01a Articolo in rivista
PV-Electrolyzer plant: models and optimization procedure / P., Artuso; F., Zuccari; Dell'Era, Alessandro; F., Orecchini. - In: JOURNAL OF SOLAR ENERGY ENGINEERING. - ISSN 0199-6231. - ELETTRONICO. - 132:(2010), pp. 1-10. (Intervento presentato al convegno 3rd International Conference on Energy Sustainability tenutosi a San Francisco, CA nel JUL 19-23, 2009) [10.1115/1.4001673].
File allegati a questo prodotto
File Dimensione Formato  
PV-Electrolyzer Plant.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 948.32 kB
Formato Adobe PDF
948.32 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/364207
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
social impact