To evaluate the accuracy of the TRIMprob in the diagnosis of prostate neoplasm. METHODS Consecutive patients referred for prostate biopsy were prospectively enrolled. Patients had history taken, physical examination by digital rectal examination (DRE) of the prostate, assessment of total and free serum prostate-specific antigen (PSA) levels, prostate transrectal ultrasonography (TRUS), and TRIMprob test. Indications for prostate biopsy included one or more of the following conditions: total serum PSA levels of 4.0 ng/mL or more, free/total serum PSA ratio of 0.18 or less, positive results on DRE, and suspicious findings on TRUS. Twelve-core, TRUS-guided biopsies were performed with local anesthesia. A blinded investigator performed the TRIMprob test; the lowest value of the signal at 465 MHz was looked for and recorded, although data of the electromagnetic signal at 930 and 1295 MHz were also recorded. RESULTS One hundred eleven patients (aged 64.9 8.1 years, mean standard deviation), enrolled between November 2004 and August 2005, were analyzed. Total serum PSA level was 8.4 3.6 ng/mL, and free/total serum PSA ratio was 0.15 0.7. TRIMprob sensitivity for the diagnosis of prostate cancer was 0.86%; specificity and positive and negative predictive values were 0.60 and 0.88; accuracy was 72%. TRIMprob accuracy outperformed any other diagnostic parameter considered, including the rule of chance. The association of TRIMprob and DRE offered a sensitivity and a negative predictive value of 0.86% or greater. CONCLUSIONS TRIMprob had the highest accuracy rate, among all other tests, for the diagnosis of prostate cancer. Electromagnetic detection with the TRIMprob test seems to be a promising technology and a useful additional tool for the early detection of prostate cancer.

The electromagnetic detection of prostatic cancer: Evaluation of diagnostic accuracy / Tubaro, Andrea; DE NUNZIO, Cosimo; Trucchi, Alberto; Stoppacciaro, Antonella; Miano, Lucio. - In: UROLOGY. - ISSN 0090-4295. - 72:2(2008), pp. 340-344. [10.1016/j.urology.2007.11.058]

The electromagnetic detection of prostatic cancer: Evaluation of diagnostic accuracy

TUBARO, ANDREA;DE NUNZIO, Cosimo;TRUCCHI, Alberto;STOPPACCIARO, ANTONELLA;MIANO, Lucio
2008

Abstract

To evaluate the accuracy of the TRIMprob in the diagnosis of prostate neoplasm. METHODS Consecutive patients referred for prostate biopsy were prospectively enrolled. Patients had history taken, physical examination by digital rectal examination (DRE) of the prostate, assessment of total and free serum prostate-specific antigen (PSA) levels, prostate transrectal ultrasonography (TRUS), and TRIMprob test. Indications for prostate biopsy included one or more of the following conditions: total serum PSA levels of 4.0 ng/mL or more, free/total serum PSA ratio of 0.18 or less, positive results on DRE, and suspicious findings on TRUS. Twelve-core, TRUS-guided biopsies were performed with local anesthesia. A blinded investigator performed the TRIMprob test; the lowest value of the signal at 465 MHz was looked for and recorded, although data of the electromagnetic signal at 930 and 1295 MHz were also recorded. RESULTS One hundred eleven patients (aged 64.9 8.1 years, mean standard deviation), enrolled between November 2004 and August 2005, were analyzed. Total serum PSA level was 8.4 3.6 ng/mL, and free/total serum PSA ratio was 0.15 0.7. TRIMprob sensitivity for the diagnosis of prostate cancer was 0.86%; specificity and positive and negative predictive values were 0.60 and 0.88; accuracy was 72%. TRIMprob accuracy outperformed any other diagnostic parameter considered, including the rule of chance. The association of TRIMprob and DRE offered a sensitivity and a negative predictive value of 0.86% or greater. CONCLUSIONS TRIMprob had the highest accuracy rate, among all other tests, for the diagnosis of prostate cancer. Electromagnetic detection with the TRIMprob test seems to be a promising technology and a useful additional tool for the early detection of prostate cancer.
2008
01 Pubblicazione su rivista::01a Articolo in rivista
The electromagnetic detection of prostatic cancer: Evaluation of diagnostic accuracy / Tubaro, Andrea; DE NUNZIO, Cosimo; Trucchi, Alberto; Stoppacciaro, Antonella; Miano, Lucio. - In: UROLOGY. - ISSN 0090-4295. - 72:2(2008), pp. 340-344. [10.1016/j.urology.2007.11.058]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/364162
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 13
social impact