Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
ANTARES is a high-energy neutrino telescope installed in the Mediterranean Sea at a depth of 2475 m. It consists of a three-dimensional array of optical modules, each containing a large photomultiplier tube. A total of 2700 front-end ASICs named analogue ring samplers (ARS) process the phototube signals, measure their arrival time, amplitude and shape as well as perform monitoring and calibration tasks. The ARS chip processes the analogue signals from the optical modules and converts information into digital data. All the information is transmitted to shore through further multiplexing electronics and an optical link. This paper describes the performance of the ARS chip: results from the functionality and characterization tests in the laboratory are summarized and the long-term performance in the apparatus is illustrated. (C) 2010 Elsevier B.V. All rights reserved.
Performance of the front-end electronics of the ANTARES neutrino telescope / J. A., Aguilar; I., Al Samarai; A., Albert; M., Anghinolfi; G., Anton; S., Anvar; M., Ardid; A. C., Assis Jesus; T., Astraatmadja; J. J., Aubert; R., Auer; B., Baret; S., Basa; M., Bazzotti; V., Bertin; S., Biagi; C., Bigongiari; M., Bou Cabo; M. C., Bouwhuis; A., Brown; J., Brunner; J., Busto; F. I., Camarena; Capone, Antonio; L., Caponetto; C., Carloganu; G., Carminati; J., Carr; E., Castorina; V., Cavasinni; S. I., Cecchini; T. H., Chaleil; P. H., Charvis; T., Chiarusi; N., Chon Sen; M., Circella; H., Costantini; N., Cottini; P., Coyle; C., Curtil; DE BONIS, Giulia; N., De Botton; I., Dekeyser; E., Delagnes; A., Deschamps; C., Distefano; C., Donzaud; D., Dornic; D., Drouhin; F., Druillole; T., Eberl; U., Emanuele; J. P., Ernenwein; S., Escoffier; E., Falchini; F., Fehr; F., Feinstein; V., Flaminio; J., Fopma; K., Fratini; U., Fritsch; J. L., Fuda; P., Gay; G., Giacomelli; J. P., Gomez Gonzalez; K., Graf; G., Guillard; G., Halladjian; G., Hallewell; Hoffmann C., Van Haren; A. J., Heijboer; Y., Hello; Hernandez, ; J. J., Rey; B., Herold; J., Hossl; M., De Jong; N., Kalantar Nayestanaki; O., Kalekin; A., Kappes; U., Katz; P., Kooijman; C., Kopper; A., Kouchner; W., Kretschmer; D., Lachartre; H., Lafoux; R., Lahmann; P., Lamare; G., Lambard; G., Larosa; H., Laschinsky; H., Le Provost; A., Le Van Suu; D., Lefevre; T., Legou; G., Lelaizant; G., Lim; D., Lo Presti; H., Loehner; S., Loucatos; Lucarelli, Fabrizio; S., Mangano; M., Marcelin; A., Margiotta; J. A., Martinez Mora; A., Mazure; E., Monmarthe; T., Montaruli; M., Morganti; L., Moscoso; H., Motz; C., Naumann; M., Neff; C. H., Olivetto; R., Ostasch; D., Palioselitis; G. E., Pavalas; P., Payre; J., Petrovic; P., Piattelli; N., Picot Clemente; C., Picq; J. P., Pneau; J., Poinsignon; V., Popa; T., Pradier; E., Presani; C., Racca; A., Radu; C., Reed; F., Rethore; G., Riccobene; C., Richardt; M., Rujoiu; G. V., Russo; F., Salesa; P., Sapienza; F., Schoeck; J. P., Schuller; R., Shanidze; Simeone, Francesco; M., Spurio; J. J. M., Steijger; T. H., Stolarczyk; C., Tamburini; L., Tasca; S., Toscano; B., Vallage; V., Van Elewyck; G., Vannoni; Vecchi, Manuela; P., Vernin; G., Wijnker; E., De Wolf; H., Yepes; D., Zaborov; J. D., Zornoza; J., Zuniga. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 622:1(2010), pp. 59-73. [10.1016/j.nima.2010.06.225]
Performance of the front-end electronics of the ANTARES neutrino telescope
J. A. Aguilar;I. Al Samarai;A. Albert;M. Anghinolfi;G. Anton;S. Anvar;M. Ardid;A. C. Assis Jesus;T. Astraatmadja;J. J. Aubert;R. Auer;B. Baret;S. Basa;M. Bazzotti;V. Bertin;S. Biagi;C. Bigongiari;M. Bou Cabo;M. C. Bouwhuis;A. Brown;J. Brunner;J. Busto;F. I. Camarena;CAPONE, Antonio;L. Caponetto;C. Carloganu;G. Carminati;J. Carr;E. Castorina;V. Cavasinni;S. I. Cecchini;T. H. Chaleil;P. H. Charvis;T. Chiarusi;N. Chon Sen;M. Circella;H. Costantini;N. Cottini;P. Coyle;C. Curtil;DE BONIS, Giulia;N. De Botton;I. Dekeyser;E. Delagnes;A. Deschamps;C. Distefano;C. Donzaud;D. Dornic;D. Drouhin;F. Druillole;T. Eberl;U. Emanuele;J. P. Ernenwein;S. Escoffier;E. Falchini;F. Fehr;F. Feinstein;V. Flaminio;J. Fopma;K. Fratini;U. Fritsch;J. L. Fuda;P. Gay;G. Giacomelli;J. P. Gomez Gonzalez;K. Graf;G. Guillard;G. Halladjian;G. Hallewell;Hoffmann C. Van Haren;A. J. Heijboer;Y. Hello;Hernandez;J. J. Rey;B. Herold;J. Hossl;M. De Jong;N. Kalantar Nayestanaki;O. Kalekin;A. Kappes;U. Katz;P. Kooijman;C. Kopper;A. Kouchner;W. Kretschmer;D. Lachartre;H. Lafoux;R. Lahmann;P. Lamare;G. Lambard;G. Larosa;H. Laschinsky;H. Le Provost;A. Le Van Suu;D. Lefevre;T. Legou;G. Lelaizant;G. Lim;D. Lo Presti;H. Loehner;S. Loucatos;LUCARELLI, FABRIZIO;S. Mangano;M. Marcelin;A. Margiotta;J. A. Martinez Mora;A. Mazure;E. Monmarthe;T. Montaruli;M. Morganti;L. Moscoso;H. Motz;C. Naumann;M. Neff;C. H. Olivetto;R. Ostasch;D. Palioselitis;G. E. Pavalas;P. Payre;J. Petrovic;P. Piattelli;N. Picot Clemente;C. Picq;J. P. Pneau;J. Poinsignon;V. Popa;T. Pradier;E. Presani;C. Racca;A. Radu;C. Reed;F. Rethore;G. Riccobene;C. Richardt;M. Rujoiu;G. V. Russo;F. Salesa;P. Sapienza;F. Schoeck;J. P. Schuller;R. Shanidze;SIMEONE, Francesco;M. Spurio;J. J. M. Steijger;T. H. Stolarczyk;C. Tamburini;L. Tasca;S. Toscano;B. Vallage;V. Van Elewyck;G. Vannoni;VECCHI, MANUELA;P. Vernin;G. Wijnker;E. De Wolf;H. Yepes;D. Zaborov;J. D. Zornoza;J. Zuniga
2010
Abstract
ANTARES is a high-energy neutrino telescope installed in the Mediterranean Sea at a depth of 2475 m. It consists of a three-dimensional array of optical modules, each containing a large photomultiplier tube. A total of 2700 front-end ASICs named analogue ring samplers (ARS) process the phototube signals, measure their arrival time, amplitude and shape as well as perform monitoring and calibration tasks. The ARS chip processes the analogue signals from the optical modules and converts information into digital data. All the information is transmitted to shore through further multiplexing electronics and an optical link. This paper describes the performance of the ARS chip: results from the functionality and characterization tests in the laboratory are summarized and the long-term performance in the apparatus is illustrated. (C) 2010 Elsevier B.V. All rights reserved.
01 Pubblicazione su rivista::01a Articolo in rivista
Performance of the front-end electronics of the ANTARES neutrino telescope / J. A., Aguilar; I., Al Samarai; A., Albert; M., Anghinolfi; G., Anton; S., Anvar; M., Ardid; A. C., Assis Jesus; T., Astraatmadja; J. J., Aubert; R., Auer; B., Baret; S., Basa; M., Bazzotti; V., Bertin; S., Biagi; C., Bigongiari; M., Bou Cabo; M. C., Bouwhuis; A., Brown; J., Brunner; J., Busto; F. I., Camarena; Capone, Antonio; L., Caponetto; C., Carloganu; G., Carminati; J., Carr; E., Castorina; V., Cavasinni; S. I., Cecchini; T. H., Chaleil; P. H., Charvis; T., Chiarusi; N., Chon Sen; M., Circella; H., Costantini; N., Cottini; P., Coyle; C., Curtil; DE BONIS, Giulia; N., De Botton; I., Dekeyser; E., Delagnes; A., Deschamps; C., Distefano; C., Donzaud; D., Dornic; D., Drouhin; F., Druillole; T., Eberl; U., Emanuele; J. P., Ernenwein; S., Escoffier; E., Falchini; F., Fehr; F., Feinstein; V., Flaminio; J., Fopma; K., Fratini; U., Fritsch; J. L., Fuda; P., Gay; G., Giacomelli; J. P., Gomez Gonzalez; K., Graf; G., Guillard; G., Halladjian; G., Hallewell; Hoffmann C., Van Haren; A. J., Heijboer; Y., Hello; Hernandez, ; J. J., Rey; B., Herold; J., Hossl; M., De Jong; N., Kalantar Nayestanaki; O., Kalekin; A., Kappes; U., Katz; P., Kooijman; C., Kopper; A., Kouchner; W., Kretschmer; D., Lachartre; H., Lafoux; R., Lahmann; P., Lamare; G., Lambard; G., Larosa; H., Laschinsky; H., Le Provost; A., Le Van Suu; D., Lefevre; T., Legou; G., Lelaizant; G., Lim; D., Lo Presti; H., Loehner; S., Loucatos; Lucarelli, Fabrizio; S., Mangano; M., Marcelin; A., Margiotta; J. A., Martinez Mora; A., Mazure; E., Monmarthe; T., Montaruli; M., Morganti; L., Moscoso; H., Motz; C., Naumann; M., Neff; C. H., Olivetto; R., Ostasch; D., Palioselitis; G. E., Pavalas; P., Payre; J., Petrovic; P., Piattelli; N., Picot Clemente; C., Picq; J. P., Pneau; J., Poinsignon; V., Popa; T., Pradier; E., Presani; C., Racca; A., Radu; C., Reed; F., Rethore; G., Riccobene; C., Richardt; M., Rujoiu; G. V., Russo; F., Salesa; P., Sapienza; F., Schoeck; J. P., Schuller; R., Shanidze; Simeone, Francesco; M., Spurio; J. J. M., Steijger; T. H., Stolarczyk; C., Tamburini; L., Tasca; S., Toscano; B., Vallage; V., Van Elewyck; G., Vannoni; Vecchi, Manuela; P., Vernin; G., Wijnker; E., De Wolf; H., Yepes; D., Zaborov; J. D., Zornoza; J., Zuniga. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 622:1(2010), pp. 59-73. [10.1016/j.nima.2010.06.225]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/363839
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
57
51
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.