In this paper. we describe a validation procedure for chemical fractionation analysis of elements (Al, As, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni. Pb, S, Sb, Si, Sr, Ti and V) and soluble ions (Cl(-), NO(3)(-), SO(4)(2-), Na(+), NH(4)(+), Mg(2+), Ca(2+)) in suspended particulate matter (PM). The procedure applies three distinct measurement techniques (XRF, IC and ICP-OES) to the analysis of individual samples. The techniques used generate different Outputs at different stages in the procedure. This makes it possible to identify the contributions of specific parameters to measurement uncertainty. On this basis, we propose a scheme for controlling the analytical quality of data from individual samples in which inter-technique comparisons is used in the same way many analytical methods use surrogates. We apply this scheme to about 310 samples of PM(10) and PM(2.5) identifying and assessing the main factors contributing to measurement uncertainty. This procedure successfully resolved a number of difficulties frequently encountered during the analysis of PM, including lack of appropriate reference materials and the low reliability of alternative techniques of quality control. The results demonstrate the critical importance of sample treatment prior to destructive analysis by IC and ICP. (C) 2008 Elsevier B.V. All rights reserved.

Determination of soluble ions and elements in ambient air suspended particulate matter: Inter-technique comparison of XRF, IC and ICP for sample-by-sample quality control / Canepari, Silvia; C., Perrino; Astolfi, Maria Luisa; M., Catrambone; Perret, Daniela. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 77:5(2009), pp. 1821-1829. [10.1016/j.talanta.2008.10.029]

Determination of soluble ions and elements in ambient air suspended particulate matter: Inter-technique comparison of XRF, IC and ICP for sample-by-sample quality control

CANEPARI, Silvia;ASTOLFI, Maria Luisa;PERRET, Daniela
2009

Abstract

In this paper. we describe a validation procedure for chemical fractionation analysis of elements (Al, As, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni. Pb, S, Sb, Si, Sr, Ti and V) and soluble ions (Cl(-), NO(3)(-), SO(4)(2-), Na(+), NH(4)(+), Mg(2+), Ca(2+)) in suspended particulate matter (PM). The procedure applies three distinct measurement techniques (XRF, IC and ICP-OES) to the analysis of individual samples. The techniques used generate different Outputs at different stages in the procedure. This makes it possible to identify the contributions of specific parameters to measurement uncertainty. On this basis, we propose a scheme for controlling the analytical quality of data from individual samples in which inter-technique comparisons is used in the same way many analytical methods use surrogates. We apply this scheme to about 310 samples of PM(10) and PM(2.5) identifying and assessing the main factors contributing to measurement uncertainty. This procedure successfully resolved a number of difficulties frequently encountered during the analysis of PM, including lack of appropriate reference materials and the low reliability of alternative techniques of quality control. The results demonstrate the critical importance of sample treatment prior to destructive analysis by IC and ICP. (C) 2008 Elsevier B.V. All rights reserved.
2009
chemical characterization; chemical fractionation analysis; inter technique comparison; inter-technique comparison; particulate matter; quality control
01 Pubblicazione su rivista::01a Articolo in rivista
Determination of soluble ions and elements in ambient air suspended particulate matter: Inter-technique comparison of XRF, IC and ICP for sample-by-sample quality control / Canepari, Silvia; C., Perrino; Astolfi, Maria Luisa; M., Catrambone; Perret, Daniela. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 77:5(2009), pp. 1821-1829. [10.1016/j.talanta.2008.10.029]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/362611
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 60
social impact