In this paper. we describe a validation procedure for chemical fractionation analysis of elements (Al, As, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni. Pb, S, Sb, Si, Sr, Ti and V) and soluble ions (Cl(-), NO(3)(-), SO(4)(2-), Na(+), NH(4)(+), Mg(2+), Ca(2+)) in suspended particulate matter (PM). The procedure applies three distinct measurement techniques (XRF, IC and ICP-OES) to the analysis of individual samples. The techniques used generate different Outputs at different stages in the procedure. This makes it possible to identify the contributions of specific parameters to measurement uncertainty. On this basis, we propose a scheme for controlling the analytical quality of data from individual samples in which inter-technique comparisons is used in the same way many analytical methods use surrogates. We apply this scheme to about 310 samples of PM(10) and PM(2.5) identifying and assessing the main factors contributing to measurement uncertainty. This procedure successfully resolved a number of difficulties frequently encountered during the analysis of PM, including lack of appropriate reference materials and the low reliability of alternative techniques of quality control. The results demonstrate the critical importance of sample treatment prior to destructive analysis by IC and ICP. (C) 2008 Elsevier B.V. All rights reserved.
Determination of soluble ions and elements in ambient air suspended particulate matter: Inter-technique comparison of XRF, IC and ICP for sample-by-sample quality control / Canepari, Silvia; C., Perrino; Astolfi, Maria Luisa; M., Catrambone; Perret, Daniela. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 77:5(2009), pp. 1821-1829. [10.1016/j.talanta.2008.10.029]
Determination of soluble ions and elements in ambient air suspended particulate matter: Inter-technique comparison of XRF, IC and ICP for sample-by-sample quality control
CANEPARI, Silvia;ASTOLFI, Maria Luisa;PERRET, Daniela
2009
Abstract
In this paper. we describe a validation procedure for chemical fractionation analysis of elements (Al, As, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni. Pb, S, Sb, Si, Sr, Ti and V) and soluble ions (Cl(-), NO(3)(-), SO(4)(2-), Na(+), NH(4)(+), Mg(2+), Ca(2+)) in suspended particulate matter (PM). The procedure applies three distinct measurement techniques (XRF, IC and ICP-OES) to the analysis of individual samples. The techniques used generate different Outputs at different stages in the procedure. This makes it possible to identify the contributions of specific parameters to measurement uncertainty. On this basis, we propose a scheme for controlling the analytical quality of data from individual samples in which inter-technique comparisons is used in the same way many analytical methods use surrogates. We apply this scheme to about 310 samples of PM(10) and PM(2.5) identifying and assessing the main factors contributing to measurement uncertainty. This procedure successfully resolved a number of difficulties frequently encountered during the analysis of PM, including lack of appropriate reference materials and the low reliability of alternative techniques of quality control. The results demonstrate the critical importance of sample treatment prior to destructive analysis by IC and ICP. (C) 2008 Elsevier B.V. All rights reserved.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.