A combination of PIV/OH laser induced fluorescence technique is used to measure the conditional burned and unburned - gas velocity in a turbulent premixed CH(4)/air annular bluff-body stabilized burner. By changing the equivalence ratio from lean to almost stoichiometric, the energy budget of the recirculating region anchoring the flame is altered in such a way to increasingly lift the flame away from the jet exit. The overall turbulence intensity interacting with each flame is thus systematically varied in a significant range, allowing for a parametric study of its effect on turbulent scalar transport under well controlled conditions, always well within the flamelet regime. The component of the flux normal to the average front is found to reverse its direction, confirming the Bray number as a good indicator of gradient/counter-gradient behavior, once the actual incoming turbulence level felt locally by the flame is assumed as the proper control parameter. (C) 2008 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Counter-gradient transport in the combustion of a premixed CH_4/Air annular jet by combined PIV/OH-LIF / Troiani, Guido; Marrocco, Mauro; S., Giammartini; Casciola, Carlo Massimo. - In: COMBUSTION AND FLAME. - ISSN 0010-2180. - STAMPA. - 156 (3):(2009), pp. 608-620. [10.1016/j.combustflame.2008.12.010]

Counter-gradient transport in the combustion of a premixed CH_4/Air annular jet by combined PIV/OH-LIF

TROIANI, Guido;MARROCCO, MAURO;CASCIOLA, Carlo Massimo
2009

Abstract

A combination of PIV/OH laser induced fluorescence technique is used to measure the conditional burned and unburned - gas velocity in a turbulent premixed CH(4)/air annular bluff-body stabilized burner. By changing the equivalence ratio from lean to almost stoichiometric, the energy budget of the recirculating region anchoring the flame is altered in such a way to increasingly lift the flame away from the jet exit. The overall turbulence intensity interacting with each flame is thus systematically varied in a significant range, allowing for a parametric study of its effect on turbulent scalar transport under well controlled conditions, always well within the flamelet regime. The component of the flux normal to the average front is found to reverse its direction, confirming the Bray number as a good indicator of gradient/counter-gradient behavior, once the actual incoming turbulence level felt locally by the flame is assumed as the proper control parameter. (C) 2008 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
2009
01 Pubblicazione su rivista::01a Articolo in rivista
Counter-gradient transport in the combustion of a premixed CH_4/Air annular jet by combined PIV/OH-LIF / Troiani, Guido; Marrocco, Mauro; S., Giammartini; Casciola, Carlo Massimo. - In: COMBUSTION AND FLAME. - ISSN 0010-2180. - STAMPA. - 156 (3):(2009), pp. 608-620. [10.1016/j.combustflame.2008.12.010]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/361973
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 23
social impact