Objective: To evaluate dose reduction and image quality in coronary 64-slice multidetector computed tomography using an automatic exposure control system (AECs). Methods: A total of 101 patients were divided into 4 groups. Tube current was 600 and 800 mAs in groups A and B and adapted at 600 and 800 quality-reference mAs using an AECs in groups C and D. Effective dose and organ-equivalent dose were evaluated. Image noise was quantified as standard deviation of air-space attenuation. Two observers assessed technical adequacy and image quality using a 4-point scale. Results: Effective dose ranged from 8.6 mSv (group C) to 15 mSv (group 13) with significant dose reduction for examinations perfornied at 600 mAs (21.7%) and 800 mAs (29.4%). Contribution of organ-equivalent doses showed higher exposure for lungs (42%) and breast (22%). Noise was significantly higher in groups studied with AECs. Larger coronary segments resulted in higher image quality scores without differences between groups. Conclusion: Automatic exposure control systems provides images of diagnostic quality with substantial dose reduction.

Dose Reduction and Image Quality Assessment in 64-Detector Row Computed Tomography of the Coronary Arteries Using an Automatic Exposure Control System / Francone, Marco; DI CASTRO, Elisabetta; Napoli, Alessandro; Chiara, Bolzan; Carbone, Iacopo; Linda, Bertoletti; Iuliano, Luigi; Catalano, Carlo; Passariello, Roberto. - In: JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY. - ISSN 0363-8715. - STAMPA. - 32:5(2008), pp. 668-678. [10.1097/rct.0b013e31815ea873]

Dose Reduction and Image Quality Assessment in 64-Detector Row Computed Tomography of the Coronary Arteries Using an Automatic Exposure Control System

FRANCONE, MARCO;DI CASTRO, Elisabetta;NAPOLI, ALESSANDRO;CARBONE, IACOPO;IULIANO, Luigi;CATALANO, Carlo;PASSARIELLO, Roberto
2008

Abstract

Objective: To evaluate dose reduction and image quality in coronary 64-slice multidetector computed tomography using an automatic exposure control system (AECs). Methods: A total of 101 patients were divided into 4 groups. Tube current was 600 and 800 mAs in groups A and B and adapted at 600 and 800 quality-reference mAs using an AECs in groups C and D. Effective dose and organ-equivalent dose were evaluated. Image noise was quantified as standard deviation of air-space attenuation. Two observers assessed technical adequacy and image quality using a 4-point scale. Results: Effective dose ranged from 8.6 mSv (group C) to 15 mSv (group 13) with significant dose reduction for examinations perfornied at 600 mAs (21.7%) and 800 mAs (29.4%). Contribution of organ-equivalent doses showed higher exposure for lungs (42%) and breast (22%). Noise was significantly higher in groups studied with AECs. Larger coronary segments resulted in higher image quality scores without differences between groups. Conclusion: Automatic exposure control systems provides images of diagnostic quality with substantial dose reduction.
2008
automatic exposure control system (aecs); coronary mdct; dose reduction; radiation dose
01 Pubblicazione su rivista::01a Articolo in rivista
Dose Reduction and Image Quality Assessment in 64-Detector Row Computed Tomography of the Coronary Arteries Using an Automatic Exposure Control System / Francone, Marco; DI CASTRO, Elisabetta; Napoli, Alessandro; Chiara, Bolzan; Carbone, Iacopo; Linda, Bertoletti; Iuliano, Luigi; Catalano, Carlo; Passariello, Roberto. - In: JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY. - ISSN 0363-8715. - STAMPA. - 32:5(2008), pp. 668-678. [10.1097/rct.0b013e31815ea873]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/360664
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact