Images obtained by flood-field Co57 irradiation of CsI(T1) crystal arrays detectors, coupled to a metal-channel dynode PSPMT, were statistically analyzed by means of a bivariate normal distribution. For each crystal position, the planar distribution charge was described by a confidence ellipse chosen to maximize the 1-to-1 relationship between the photons incoming at each crystal and the centroid obtained from electric charge distribution. The flood-field irradiation response of a 22 mm x 22 mm CsI(T1) array, with different pixel dimensions, were studied, and the comparison between the charge distribution of a limited number of crystals following the flood-field irradiation was made. (C) 2002 Elsevier Science B.V. All rights reserved.

Statistical description of response to flood-field irradiation in scintillation crystal arrays / C., Bonifazzi; Cinti, Maria Nerina; A., Tartari; Pellegrini, Rosanna; Pani, Roberto. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 497:1(2003), pp. 179-185. (Intervento presentato al convegno 1st Topical Symposium on Functional Breast Imaging with Advanced Detectors tenutosi a ROME, ITALY nel APR 18-21, 2001) [10.1016/s0168-9002(02)01909-5].

Statistical description of response to flood-field irradiation in scintillation crystal arrays

CINTI, Maria Nerina;PELLEGRINI, Rosanna;PANI, Roberto
2003

Abstract

Images obtained by flood-field Co57 irradiation of CsI(T1) crystal arrays detectors, coupled to a metal-channel dynode PSPMT, were statistically analyzed by means of a bivariate normal distribution. For each crystal position, the planar distribution charge was described by a confidence ellipse chosen to maximize the 1-to-1 relationship between the photons incoming at each crystal and the centroid obtained from electric charge distribution. The flood-field irradiation response of a 22 mm x 22 mm CsI(T1) array, with different pixel dimensions, were studied, and the comparison between the charge distribution of a limited number of crystals following the flood-field irradiation was made. (C) 2002 Elsevier Science B.V. All rights reserved.
2003
bivariate analysis; nuclear medicine imaging; scintillation array; spatial resolution improvement
01 Pubblicazione su rivista::01a Articolo in rivista
Statistical description of response to flood-field irradiation in scintillation crystal arrays / C., Bonifazzi; Cinti, Maria Nerina; A., Tartari; Pellegrini, Rosanna; Pani, Roberto. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 497:1(2003), pp. 179-185. (Intervento presentato al convegno 1st Topical Symposium on Functional Breast Imaging with Advanced Detectors tenutosi a ROME, ITALY nel APR 18-21, 2001) [10.1016/s0168-9002(02)01909-5].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/360542
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact