A label-free absolute quantitation method based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been developed. This methodology was applied to mouse heart in order to quantify cardiac troponin T (cTnT), which is considered to be a sensitive marker of heart damage. The cTnT was extracted, isolated by reversed-phase high-performance liquid chromatography, digested, and analyzed by MALDI-TOF MS. The MS-based quantitation was performed using matrix-matched calibration curves (due to a matrix effect) of two synthetic peptides, one cTnT-specific peptide and one internal standard peptide, respectively. Recoveries at three spiking levels ranged from 87-96%, with relative standard deviations of below 10%. The method detection limit and the method quantitation limit, expressed as the amount of cTnT for the amount of total sarcomeric protein extract, were 0.03 mg g(-1) and 0.15 mg g(-1), respectively. This method appears to be accurate and generally suitable for improving absolute protein quantitation.
A label-free method based on MALDI-TOF mass spectrometry for the absolute quantitation of troponin T in mouse cardiac tissue / Bizzarri, Mariano; Cavaliere, Chiara; Foglia, Patrizia; Guarino, Chiara; Samperi, Roberto; Lagana', Aldo. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - STAMPA. - 391:5(2008), pp. 1969-1976. [10.1007/s00216-008-2113-x]
A label-free method based on MALDI-TOF mass spectrometry for the absolute quantitation of troponin T in mouse cardiac tissue
BIZZARRI, Mariano;CAVALIERE, CHIARA;FOGLIA, Patrizia;GUARINO, CHIARA;SAMPERI, Roberto;LAGANA', Aldo
2008
Abstract
A label-free absolute quantitation method based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been developed. This methodology was applied to mouse heart in order to quantify cardiac troponin T (cTnT), which is considered to be a sensitive marker of heart damage. The cTnT was extracted, isolated by reversed-phase high-performance liquid chromatography, digested, and analyzed by MALDI-TOF MS. The MS-based quantitation was performed using matrix-matched calibration curves (due to a matrix effect) of two synthetic peptides, one cTnT-specific peptide and one internal standard peptide, respectively. Recoveries at three spiking levels ranged from 87-96%, with relative standard deviations of below 10%. The method detection limit and the method quantitation limit, expressed as the amount of cTnT for the amount of total sarcomeric protein extract, were 0.03 mg g(-1) and 0.15 mg g(-1), respectively. This method appears to be accurate and generally suitable for improving absolute protein quantitation.File | Dimensione | Formato | |
---|---|---|---|
Bizzarri_A-label-free_2008.pdf
solo gestori archivio
Note: full text - editor PDF
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
231.76 kB
Formato
Adobe PDF
|
231.76 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.