Kinematic and kinetic methods (sacral marker, reconstructed pelvis, segmental analysis, and force platform methods) have been used to calculate the vertical excursion of the center of mass (COM) during movement. In this study we compared the measurement of vertical COM displacement yielded by different methods during able-bodied subjects' hopping at different frequencies (varying between 1.2 and 3.2 Hz). ANOVA revealed a significant interaction between hopping frequency and method (p < 0.001), showing that increasing hopping frequency reduced the differences between methods. A post hoc analysis revealed a significant difference between all methods at the lowest hopping frequency and between the force platform and both the sacral marker and reconstructed pelvis methods at the intermediate hopping frequencies, with differences ranging from 16 to 67 millimeters (all p < 0.05). Results are discussed in view of each methods' limits. We conclude that the segmental analysis and force platform methods can be considered to provide the most accurate results for COM vertical excursion during human hopping in a large range of hopping frequency.

Comparison Between Kinematic and Kinetic Methods for Computing the Vertical Displacement of the Center of Mass During Human Hopping at Different Frequencies / A., Ranavolo; R., Don; A., Cacchio; Serrao, Mariano; Paoloni, Marco; Mangone, Massimiliano; Santilli, Valter. - In: JOURNAL OF APPLIED BIOMECHANICS. - ISSN 1065-8483. - STAMPA. - 24:3(2008), pp. 271-279.

Comparison Between Kinematic and Kinetic Methods for Computing the Vertical Displacement of the Center of Mass During Human Hopping at Different Frequencies

SERRAO, Mariano;PAOLONI, Marco;MANGONE, MASSIMILIANO;SANTILLI, VALTER
2008

Abstract

Kinematic and kinetic methods (sacral marker, reconstructed pelvis, segmental analysis, and force platform methods) have been used to calculate the vertical excursion of the center of mass (COM) during movement. In this study we compared the measurement of vertical COM displacement yielded by different methods during able-bodied subjects' hopping at different frequencies (varying between 1.2 and 3.2 Hz). ANOVA revealed a significant interaction between hopping frequency and method (p < 0.001), showing that increasing hopping frequency reduced the differences between methods. A post hoc analysis revealed a significant difference between all methods at the lowest hopping frequency and between the force platform and both the sacral marker and reconstructed pelvis methods at the intermediate hopping frequencies, with differences ranging from 16 to 67 millimeters (all p < 0.05). Results are discussed in view of each methods' limits. We conclude that the segmental analysis and force platform methods can be considered to provide the most accurate results for COM vertical excursion during human hopping in a large range of hopping frequency.
2008
biomechanics; movement analysis; stiffness
01 Pubblicazione su rivista::01a Articolo in rivista
Comparison Between Kinematic and Kinetic Methods for Computing the Vertical Displacement of the Center of Mass During Human Hopping at Different Frequencies / A., Ranavolo; R., Don; A., Cacchio; Serrao, Mariano; Paoloni, Marco; Mangone, Massimiliano; Santilli, Valter. - In: JOURNAL OF APPLIED BIOMECHANICS. - ISSN 1065-8483. - STAMPA. - 24:3(2008), pp. 271-279.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/358155
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
social impact