Background: Novel implant surface treatments with a nanothickness bioactive ceramic deposition onto rough surfaces have been recently introduced. This study aims to evaluate histologically and histomorphometrically (bone-to-implant contact [BIC] and bone area fraction occupancy [BAFO]) the early bone response to plasma-sprayed calcium phosphate (PSCaP)-coated versus a 300- to 500-nm thickness bioactive ceramic nano-coated plateau root form implants in a rabbit femur model. Methods: A total of 48 plateau root form implants were bilaterally placed in the distal aspect of the femur of 12 white New Zealand rabbits, remaining for 20, 30, and 60 days in vivo (n = 4 animals per time in vivo, n = 2 implants per surface per animal). After sacrifice, the implants in bone were non-decalcified processed to slides of approximately 30 mu m thickness, and were morphologically and morphometrically (BIC and BAFO) evaluated. Results: Higher degrees of bone structural organization were temporally observed for the PSCaP surface compared to the nano surface over time. BIC and BAFO was significantly higher (P<0.05) for PSCaP at all implantation times evaluated. Conclusions: Within the limits of this study it is possible to state that bioactive ceramic coatings of both thicknesses were biocompatible and osteoconductive. However, the early bone response was favored by the presence of the thicker PSCaP coating. J Periodontol 2010;81:556-561.

A histomorphometric study of nanothickness and plasma-sprayed calcium-phosphorous-coated implant surfaces in rabbit bone / Quaranta, Alessandro; Giovanna, Iezzi; Antonio, Scarano; Paulo G., Coelho; Vozza, Iole; Mauro, Marincola; Adriano, Piattelli. - In: JOURNAL OF PERIODONTOLOGY. - ISSN 0022-3492. - STAMPA. - 81:4(2010), pp. 556-561. [10.1902/jop.2010.090296]

A histomorphometric study of nanothickness and plasma-sprayed calcium-phosphorous-coated implant surfaces in rabbit bone.

QUARANTA, ALESSANDRO;VOZZA, Iole;
2010

Abstract

Background: Novel implant surface treatments with a nanothickness bioactive ceramic deposition onto rough surfaces have been recently introduced. This study aims to evaluate histologically and histomorphometrically (bone-to-implant contact [BIC] and bone area fraction occupancy [BAFO]) the early bone response to plasma-sprayed calcium phosphate (PSCaP)-coated versus a 300- to 500-nm thickness bioactive ceramic nano-coated plateau root form implants in a rabbit femur model. Methods: A total of 48 plateau root form implants were bilaterally placed in the distal aspect of the femur of 12 white New Zealand rabbits, remaining for 20, 30, and 60 days in vivo (n = 4 animals per time in vivo, n = 2 implants per surface per animal). After sacrifice, the implants in bone were non-decalcified processed to slides of approximately 30 mu m thickness, and were morphologically and morphometrically (BIC and BAFO) evaluated. Results: Higher degrees of bone structural organization were temporally observed for the PSCaP surface compared to the nano surface over time. BIC and BAFO was significantly higher (P<0.05) for PSCaP at all implantation times evaluated. Conclusions: Within the limits of this study it is possible to state that bioactive ceramic coatings of both thicknesses were biocompatible and osteoconductive. However, the early bone response was favored by the presence of the thicker PSCaP coating. J Periodontol 2010;81:556-561.
2010
coated materials; dental implants; ceramics; osseointegration; biocompatible materials; animal research; histology
01 Pubblicazione su rivista::01a Articolo in rivista
A histomorphometric study of nanothickness and plasma-sprayed calcium-phosphorous-coated implant surfaces in rabbit bone / Quaranta, Alessandro; Giovanna, Iezzi; Antonio, Scarano; Paulo G., Coelho; Vozza, Iole; Mauro, Marincola; Adriano, Piattelli. - In: JOURNAL OF PERIODONTOLOGY. - ISSN 0022-3492. - STAMPA. - 81:4(2010), pp. 556-561. [10.1902/jop.2010.090296]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/357952
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 29
social impact