The normal-faulting earthquake of 6 April 2009 in the Abruzzo Region of central Italy caused heavy losses of life and substantial damage to centuries old buildings of significant cultural importance and to modern reinforcedconcrete-framed buildings with hollow masonry infill walls. Although structural deficiencies were significant and widespread, the study of the characteristics of strong motion data from the heavily affected area indicated that the short duration of strong shaking may have spared many more damaged buildings from collapsing. It is recognized that, with this caveat of shortduration shaking, the infill walls may have played a very important role in preventing further deterioration or collapse of many buildings. It is concluded that better new or retrofit construction practices that include reinforced concrete shear walls may prove helpful in reducing risks in such seismic areas of Italy, other Mediterranean countries, and even in United States, where there are large inventories of deficient structures.

Recorded Motions of the 6 April 2009 Mw 6.3 L’Aquila, Italy, Earthquake and Implications for Building Structural Damage: Overview / Çelebi, M; P., Bazzurro; L., Chiaraluce; P., Clemente; Decanini, Luis Domingo; A., DE SORTIS; W., Ellsworth; A., Gorini; E., Kalkan; S., Marcucci; G., Milana; Mollaioli, Fabrizio; M., Olivieri; D., Rinaldis; A., Rovelli; F. SABETTA AND C., Stephens. - In: EARTHQUAKE SPECTRA. - ISSN 8755-2930. - STAMPA. - 26:3(2010), pp. 651-684. [10.1193/1.3450317]

Recorded Motions of the 6 April 2009 Mw 6.3 L’Aquila, Italy, Earthquake and Implications for Building Structural Damage: Overview

DECANINI, Luis Domingo;MOLLAIOLI, Fabrizio;
2010

Abstract

The normal-faulting earthquake of 6 April 2009 in the Abruzzo Region of central Italy caused heavy losses of life and substantial damage to centuries old buildings of significant cultural importance and to modern reinforcedconcrete-framed buildings with hollow masonry infill walls. Although structural deficiencies were significant and widespread, the study of the characteristics of strong motion data from the heavily affected area indicated that the short duration of strong shaking may have spared many more damaged buildings from collapsing. It is recognized that, with this caveat of shortduration shaking, the infill walls may have played a very important role in preventing further deterioration or collapse of many buildings. It is concluded that better new or retrofit construction practices that include reinforced concrete shear walls may prove helpful in reducing risks in such seismic areas of Italy, other Mediterranean countries, and even in United States, where there are large inventories of deficient structures.
2010
01 Pubblicazione su rivista::01a Articolo in rivista
Recorded Motions of the 6 April 2009 Mw 6.3 L’Aquila, Italy, Earthquake and Implications for Building Structural Damage: Overview / Çelebi, M; P., Bazzurro; L., Chiaraluce; P., Clemente; Decanini, Luis Domingo; A., DE SORTIS; W., Ellsworth; A., Gorini; E., Kalkan; S., Marcucci; G., Milana; Mollaioli, Fabrizio; M., Olivieri; D., Rinaldis; A., Rovelli; F. SABETTA AND C., Stephens. - In: EARTHQUAKE SPECTRA. - ISSN 8755-2930. - STAMPA. - 26:3(2010), pp. 651-684. [10.1193/1.3450317]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/355448
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 88
  • ???jsp.display-item.citation.isi??? 73
social impact