Chronic obstructive pulmonary disease (COPD) is a multicomponent condition that is characterized by partially reversible airflow obstruction. Serum surfactant protein D (SP-D) is synthesized by type II pneumocytes and Clara cells and participates in surfactant homeostasis and pulmonary host defense. Serum levels of SP-D are raised in individuals with COPD but there is no correlation between the serum level of SP-D and the severity of airflow obstruction. Serum SP-D is present in different forms that may have more utility as a biomarker for COPD. We report here the development of new monoclonal antibodies to full length and cleaved SP-D. We have assessed these and existing antibodies in 98 individuals with COPD recruited to the Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints (ECLIPSE) cohort. Our data show that neither monoclonal antibodies to full length nor cleaved SP-D provide additional information over that obtained with a polyclonal antibody. Moreover, levels of serum nitrosylated-SP-D did not correlate with serum level of SP-D or any clinical phenotype of COPD. The measurement of modified SP-D is of limited value in characterising individuals with COPD.

Evaluation of Full-length, Cleaved and Nitrosylated Serum Surfactant Protein D as Biomarkers for COPD / Annelyse, Duvoix; MIRANDA BANOS, MARIA ELENA; Juan, Perez; Grith L., Sorensen; Uffe, Holmskov; Bruce C., Trapnell; Jens, Madsen; Howard W., Clark; Lisa D., Edwards; Bruce E., Miller; Ruth M., Tal Singer; David A., Lomas. - In: COPD. - ISSN 1541-2555. - 8:2(2011), pp. 79-95. [10.3109/15412555.2011.558542]

Evaluation of Full-length, Cleaved and Nitrosylated Serum Surfactant Protein D as Biomarkers for COPD

MIRANDA BANOS, MARIA ELENA;
2011

Abstract

Chronic obstructive pulmonary disease (COPD) is a multicomponent condition that is characterized by partially reversible airflow obstruction. Serum surfactant protein D (SP-D) is synthesized by type II pneumocytes and Clara cells and participates in surfactant homeostasis and pulmonary host defense. Serum levels of SP-D are raised in individuals with COPD but there is no correlation between the serum level of SP-D and the severity of airflow obstruction. Serum SP-D is present in different forms that may have more utility as a biomarker for COPD. We report here the development of new monoclonal antibodies to full length and cleaved SP-D. We have assessed these and existing antibodies in 98 individuals with COPD recruited to the Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints (ECLIPSE) cohort. Our data show that neither monoclonal antibodies to full length nor cleaved SP-D provide additional information over that obtained with a polyclonal antibody. Moreover, levels of serum nitrosylated-SP-D did not correlate with serum level of SP-D or any clinical phenotype of COPD. The measurement of modified SP-D is of limited value in characterising individuals with COPD.
2011
biomarker; copd; monoclonal antibodies; surfactant protein d
01 Pubblicazione su rivista::01a Articolo in rivista
Evaluation of Full-length, Cleaved and Nitrosylated Serum Surfactant Protein D as Biomarkers for COPD / Annelyse, Duvoix; MIRANDA BANOS, MARIA ELENA; Juan, Perez; Grith L., Sorensen; Uffe, Holmskov; Bruce C., Trapnell; Jens, Madsen; Howard W., Clark; Lisa D., Edwards; Bruce E., Miller; Ruth M., Tal Singer; David A., Lomas. - In: COPD. - ISSN 1541-2555. - 8:2(2011), pp. 79-95. [10.3109/15412555.2011.558542]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/355265
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact