In this paper, the authors perform microtensile tests of single trabeculae excised from a human femur head. One of the main issues of this work is to establish some experimental procedures for preparing and testing the specimens. The use of a well-characterized microtensile apparatus allows for a low intraspecimen dispersion of the measured stiffness. Tensile/compressive tests were chosen because they appear less sensitive to errors in the cross-sectional area measurements with respect to bending tests. By these considerations, some tensile/compressive tests of plate-like trabecular specimens have been carried out. Typical stiffness values are 74.2 N/mm for tensile tests, and 58.9 N/mm for compressive test. Another compressive test performed on a shorter specimen yielded a stiffness value of 148.3 N/mm. The maximum applied load was about 0.5 N. Rough measurements of specimens sizes yielded a Young’s modulus value ranging from 1.41 to 1.89 GPa

Microtensile measurements of single trabeculae stiffness in human femur / Bini, Fabiano; Marinozzi, A; Marinozzi, F; Patanè, F.. - In: JOURNAL OF BIOMECHANICS. - ISSN 0021-9290. - ELETTRONICO. - 35:(2002), pp. 1515-1519. [10.1016/S0021-9290(02)00182-3]

Microtensile measurements of single trabeculae stiffness in human femur

BINI, FABIANO
Primo
;
MARINOZZI F
Penultimo
;
2002

Abstract

In this paper, the authors perform microtensile tests of single trabeculae excised from a human femur head. One of the main issues of this work is to establish some experimental procedures for preparing and testing the specimens. The use of a well-characterized microtensile apparatus allows for a low intraspecimen dispersion of the measured stiffness. Tensile/compressive tests were chosen because they appear less sensitive to errors in the cross-sectional area measurements with respect to bending tests. By these considerations, some tensile/compressive tests of plate-like trabecular specimens have been carried out. Typical stiffness values are 74.2 N/mm for tensile tests, and 58.9 N/mm for compressive test. Another compressive test performed on a shorter specimen yielded a stiffness value of 148.3 N/mm. The maximum applied load was about 0.5 N. Rough measurements of specimens sizes yielded a Young’s modulus value ranging from 1.41 to 1.89 GPa
2002
Trabecula; Stiffness; Microtensile; Cancellous bone;
01 Pubblicazione su rivista::01a Articolo in rivista
Microtensile measurements of single trabeculae stiffness in human femur / Bini, Fabiano; Marinozzi, A; Marinozzi, F; Patanè, F.. - In: JOURNAL OF BIOMECHANICS. - ISSN 0021-9290. - ELETTRONICO. - 35:(2002), pp. 1515-1519. [10.1016/S0021-9290(02)00182-3]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/345828
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 54
social impact