This works deals with the best practice to operate batch membrane processes in presence of fouling. The examined case is the purification of washing olive wastewater. Firstly, previous results obtained on the same reference pilot plant are reported. The critical fluxes for both the membrane operations, that is ultrafiltration and nanofiltration in series, were determined with reference to different pollutant concentrations. It is so possible to derive the prediction equations from the best fitting of the experimental results. Then, the best strategy to fix the operating permeate flux rate is briefly discussed. A permeate flux around the predicted value of the critical flux at the end of the specific membrane batch process should be adopted in order to assure the recovery target minimizing membrane fouling. Finally, test runs were performed in order to validate the proposed methodology.

Technical optimization of a dual ultrafiltration and nanofiltration pilot plant in batch operation by means of the critical flux theory: A case study / Stoller, Marco. - In: CHEMICAL ENGINEERING AND PROCESSING. - ISSN 0255-2701. - 47:7(2008), pp. 1165-1170. [10.1016/j.cep.2007.07.012]

Technical optimization of a dual ultrafiltration and nanofiltration pilot plant in batch operation by means of the critical flux theory: A case study

STOLLER, Marco
2008

Abstract

This works deals with the best practice to operate batch membrane processes in presence of fouling. The examined case is the purification of washing olive wastewater. Firstly, previous results obtained on the same reference pilot plant are reported. The critical fluxes for both the membrane operations, that is ultrafiltration and nanofiltration in series, were determined with reference to different pollutant concentrations. It is so possible to derive the prediction equations from the best fitting of the experimental results. Then, the best strategy to fix the operating permeate flux rate is briefly discussed. A permeate flux around the predicted value of the critical flux at the end of the specific membrane batch process should be adopted in order to assure the recovery target minimizing membrane fouling. Finally, test runs were performed in order to validate the proposed methodology.
2008
critical flux; fouling; membrane; nanofiltration; optimization; process; ultrafiltration
01 Pubblicazione su rivista::01a Articolo in rivista
Technical optimization of a dual ultrafiltration and nanofiltration pilot plant in batch operation by means of the critical flux theory: A case study / Stoller, Marco. - In: CHEMICAL ENGINEERING AND PROCESSING. - ISSN 0255-2701. - 47:7(2008), pp. 1165-1170. [10.1016/j.cep.2007.07.012]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/343164
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 40
social impact