This paper summarizes observations of precursor-column formation in cylindrical wire arrays on the 1-MA MAGPIE generator at Imperial College London. Direct experimental measurements of the diameter variation during the collapse and formation phase of the precursor column taken from gated soft X-ray images are presented. Three stages in precursor-column formation are identifiable from the data: broad initial density profile, rapid contraction to small diameter, and slow expansion after formation. The variation in the minimum diameter is measured for several materials, and data show good agreement with a pressure-balance model. Stability calculations suggest that the fraction of the drive current flowing the precursor column is < 1% for Al arrays and similar to 2% for W. "4 x 4" arrays show the formation of local precursor columns close to the wire position, which exhibit differences in stability depending on the wire separation. This may be related to deceleration of the plasma flow by the B-field or current convection in the flow.

The formation of precursor structures in cylindrical and "4 x 4" wire arrays / S. C., Bott; S. V., Lebedev; S. N., Bland; J. P., Chittenden; G. N., Hall; Fas, Vidal; Marocchino, Alberto; Jba, Palmer; D. J., Ampleford; C. A., Jennings. - In: IEEE TRANSACTIONS ON PLASMA SCIENCE. - ISSN 0093-3813. - STAMPA. - 35:2(2007), pp. 165-170. (Intervento presentato al convegno 33rd International Conference on Plasma Science tenutosi a Traverse City, MI nel JUN, 2006) [10.1109/tps.2007.893253].

The formation of precursor structures in cylindrical and "4 x 4" wire arrays

MAROCCHINO, ALBERTO;
2007

Abstract

This paper summarizes observations of precursor-column formation in cylindrical wire arrays on the 1-MA MAGPIE generator at Imperial College London. Direct experimental measurements of the diameter variation during the collapse and formation phase of the precursor column taken from gated soft X-ray images are presented. Three stages in precursor-column formation are identifiable from the data: broad initial density profile, rapid contraction to small diameter, and slow expansion after formation. The variation in the minimum diameter is measured for several materials, and data show good agreement with a pressure-balance model. Stability calculations suggest that the fraction of the drive current flowing the precursor column is < 1% for Al arrays and similar to 2% for W. "4 x 4" arrays show the formation of local precursor columns close to the wire position, which exhibit differences in stability depending on the wire separation. This may be related to deceleration of the plasma flow by the B-field or current convection in the flow.
2007
precursor column; precursor plasma; wire-array; z-pinches
01 Pubblicazione su rivista::01a Articolo in rivista
The formation of precursor structures in cylindrical and "4 x 4" wire arrays / S. C., Bott; S. V., Lebedev; S. N., Bland; J. P., Chittenden; G. N., Hall; Fas, Vidal; Marocchino, Alberto; Jba, Palmer; D. J., Ampleford; C. A., Jennings. - In: IEEE TRANSACTIONS ON PLASMA SCIENCE. - ISSN 0093-3813. - STAMPA. - 35:2(2007), pp. 165-170. (Intervento presentato al convegno 33rd International Conference on Plasma Science tenutosi a Traverse City, MI nel JUN, 2006) [10.1109/tps.2007.893253].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/341573
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact