In electrical installations, each working zone and each source node present a kit of operating instructions as a logic gene. Previous papers have introduced a new approach and a language of a ternary code for operational procedures (Parise program). This paper deals with some comments on definitions and the syntax of the operational language. The same status of switching defines working zones or nodes by double operating value, free value, and packed value, thereby discriminating between decision and execution, and executed act from verification. The recommended command is a double click. The instructions have to be assembled like in a genetic cryptogram in the context of an electrical power system and of its architecture and constitution. They describe the complete and reversible evolution of the operational procedures for safe transition from a one set of switching configuration to another (waves of safe sets). Transitions maps are introduced to assist in the elaboration of operational procedures and to help the training of operators, their competence, and performance. These maps are specialized for the operational procedures more than the Karnaugh maps of digital electronics. On the basis of the logic gates, the basic equivalent mechanical connectives are defined to guide the operational procedures. A switching simulator based on electronic gates can be very useful for verifying the effects of any set of switching operations, adopting for commands the double click.

Genetic Code Of Electrical Operational Procedures: Lock-Out Systems, Simulators And Training / Parise, Giuseppe; Hesla, E; Rifaat, R.. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - 46 - issue:2 March April:(2010), pp. 569-574. [10.1109/TIA.2010.2041081]

Genetic Code Of Electrical Operational Procedures: Lock-Out Systems, Simulators And Training.

PARISE, Giuseppe;
2010

Abstract

In electrical installations, each working zone and each source node present a kit of operating instructions as a logic gene. Previous papers have introduced a new approach and a language of a ternary code for operational procedures (Parise program). This paper deals with some comments on definitions and the syntax of the operational language. The same status of switching defines working zones or nodes by double operating value, free value, and packed value, thereby discriminating between decision and execution, and executed act from verification. The recommended command is a double click. The instructions have to be assembled like in a genetic cryptogram in the context of an electrical power system and of its architecture and constitution. They describe the complete and reversible evolution of the operational procedures for safe transition from a one set of switching configuration to another (waves of safe sets). Transitions maps are introduced to assist in the elaboration of operational procedures and to help the training of operators, their competence, and performance. These maps are specialized for the operational procedures more than the Karnaugh maps of digital electronics. On the basis of the logic gates, the basic equivalent mechanical connectives are defined to guide the operational procedures. A switching simulator based on electronic gates can be very useful for verifying the effects of any set of switching operations, adopting for commands the double click.
2010
transitions maps (T-maps) and Karnaugh maps (K-maps); switching or operational procedures; free and packed values of the operational algebra; Binary and ternary codes; double click logic
01 Pubblicazione su rivista::01a Articolo in rivista
Genetic Code Of Electrical Operational Procedures: Lock-Out Systems, Simulators And Training / Parise, Giuseppe; Hesla, E; Rifaat, R.. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - 46 - issue:2 March April:(2010), pp. 569-574. [10.1109/TIA.2010.2041081]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/29095
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 11
social impact