To evaluate the efficacy and safety of an expanded polytetrafluoroethylene- fluorinated ethylene-propylene (ePTFE/FEP)-covered metallic stent in the management of malignant biliary obstruction. Eighty consecutive patients with malignant common bile duct strictures were treated by placement of 83 covered metallic stents. The stent-graft consists of an inner ePTFE/FEP lining and an outer supporting structure of nitinol wire. Clinical evaluation, assessment of serum bilirubin and liver enzyme levels were analyzed before biliary drainage, before stent-graft placement and during the follow-up period at 1, 3, 6, 9 and 12 months. Technical success was obtained in all cases. After a mean follow-up of 6.9±4.63 months, the 30-day mortality rate was 14.2%. Survival rates were 40% and 20.2% at 6 and 12 months, respectively. Stent-graft patency rates were 95.5%, 92.6% and 85.7% at 3, 6 and 12 months, respectively. Complications occurred in five patients (6.4%); among these, acute cholecystitis was observed in three patients (3.8%). A stent-graft occlusion rate of 9% was observed. The percentage of patients undergoing lifetime palliation (91%) and the midterm patency rate suggest that placement of this ePTFE/FEP-covered stent-graft is safe and highly effective in achieving biliary drainage in patients with malignant strictures of the common bile duct. © 2008 European Society of Radiology.

Management of malignant biliary obstruction: Technical and clinical results using an expanded polytetrafluoroethylene fluorinated ethylene propylene (ePTFE/FEP)-covered metallic stent after 6-year experience / Fabrizio, Fanelli; Orgera, Gianluigi; Bezzi, Mario; Rossi, Plinio; Massimiliano, Allegritti; Passariello, Roberto. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - STAMPA. - 18:5(2008), pp. 911-919. [10.1007/s00330-008-0852-x]

Management of malignant biliary obstruction: Technical and clinical results using an expanded polytetrafluoroethylene fluorinated ethylene propylene (ePTFE/FEP)-covered metallic stent after 6-year experience

ORGERA, GIANLUIGI;BEZZI, Mario;ROSSI, Plinio;PASSARIELLO, Roberto
2008

Abstract

To evaluate the efficacy and safety of an expanded polytetrafluoroethylene- fluorinated ethylene-propylene (ePTFE/FEP)-covered metallic stent in the management of malignant biliary obstruction. Eighty consecutive patients with malignant common bile duct strictures were treated by placement of 83 covered metallic stents. The stent-graft consists of an inner ePTFE/FEP lining and an outer supporting structure of nitinol wire. Clinical evaluation, assessment of serum bilirubin and liver enzyme levels were analyzed before biliary drainage, before stent-graft placement and during the follow-up period at 1, 3, 6, 9 and 12 months. Technical success was obtained in all cases. After a mean follow-up of 6.9±4.63 months, the 30-day mortality rate was 14.2%. Survival rates were 40% and 20.2% at 6 and 12 months, respectively. Stent-graft patency rates were 95.5%, 92.6% and 85.7% at 3, 6 and 12 months, respectively. Complications occurred in five patients (6.4%); among these, acute cholecystitis was observed in three patients (3.8%). A stent-graft occlusion rate of 9% was observed. The percentage of patients undergoing lifetime palliation (91%) and the midterm patency rate suggest that placement of this ePTFE/FEP-covered stent-graft is safe and highly effective in achieving biliary drainage in patients with malignant strictures of the common bile duct. © 2008 European Society of Radiology.
2008
biliary; covered; malignant; obstructive jaundice; stent; stricture
01 Pubblicazione su rivista::01a Articolo in rivista
Management of malignant biliary obstruction: Technical and clinical results using an expanded polytetrafluoroethylene fluorinated ethylene propylene (ePTFE/FEP)-covered metallic stent after 6-year experience / Fabrizio, Fanelli; Orgera, Gianluigi; Bezzi, Mario; Rossi, Plinio; Massimiliano, Allegritti; Passariello, Roberto. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - STAMPA. - 18:5(2008), pp. 911-919. [10.1007/s00330-008-0852-x]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/27303
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 31
social impact