A novel methodology for simultaneous strain and temperature measurements by means of an ac powered electrical resistance strain gauge connected to a strain conditioner using thermocouple wires is proposed and validated. To this aim a specific device has been designed and implemented; the characteristics of the electronic circuit for signal conditioning have then been tested in order to determine the overall performances in temperature and strain measurements. The field verification of the method is conducted by imposing strain fields in the range from 0 to about 700 mm/m and temperature variations in the range from 210 to 100 °C. The difference between the strain measured by the proposed device and the one evaluated by a conventional digital strain meter was always less than 4 mm/m while the mean temperature discrepancy was 0.5 °C with respect to the reference temperature measured with a K-type thermocouple. Finally, compensation of temperature effects on the actual strain value has been performed while the temperature ranges from ambient to 100 °C with a residual error value of 1.461 mm/m.

The strain gage-thermocouple: a novel device for simultaneous strain and temperature measurement / Cappa, Paolo; Marinozzi, Franco; S. A., Sciuto. - In: REVIEW OF SCIENTIFIC INSTRUMENTS. - ISSN 0034-6748. - STAMPA. - 72:(2001), pp. 193-197. [10.1063/1.1329903]

The strain gage-thermocouple: a novel device for simultaneous strain and temperature measurement

CAPPA, Paolo;MARINOZZI, Franco;
2001

Abstract

A novel methodology for simultaneous strain and temperature measurements by means of an ac powered electrical resistance strain gauge connected to a strain conditioner using thermocouple wires is proposed and validated. To this aim a specific device has been designed and implemented; the characteristics of the electronic circuit for signal conditioning have then been tested in order to determine the overall performances in temperature and strain measurements. The field verification of the method is conducted by imposing strain fields in the range from 0 to about 700 mm/m and temperature variations in the range from 210 to 100 °C. The difference between the strain measured by the proposed device and the one evaluated by a conventional digital strain meter was always less than 4 mm/m while the mean temperature discrepancy was 0.5 °C with respect to the reference temperature measured with a K-type thermocouple. Finally, compensation of temperature effects on the actual strain value has been performed while the temperature ranges from ambient to 100 °C with a residual error value of 1.461 mm/m.
2001
01 Pubblicazione su rivista::01a Articolo in rivista
The strain gage-thermocouple: a novel device for simultaneous strain and temperature measurement / Cappa, Paolo; Marinozzi, Franco; S. A., Sciuto. - In: REVIEW OF SCIENTIFIC INSTRUMENTS. - ISSN 0034-6748. - STAMPA. - 72:(2001), pp. 193-197. [10.1063/1.1329903]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/256488
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 6
social impact