To determine and present the initial technical and clinical results of using an expanded polytetrafluoroethylene-fluorinated ethylene propylene (ePTFE-FEP)-covered biliary endoprosthesis to treat malignant biliary obstruction. MATERIALS AND METHODS: This prospective nonrandomized study included 42 patients with malignant obstruction of the common bile duct, common hepatic duct, and hilar confluence. Unilateral (n = 38) or bilateral (n = 4) bile duct drainage was performed by using fully covered endoprostheses with anchoring fins. To avoid branch duct blockage, endoprostheses with drainage holes at the proximal end were available. Procedure- and device-related complications were recorded. Patient survival and stent patency rates were calculated with Kaplan-Meier survival analysis. Mean follow-up bilirubin and alkaline phosphatase levels were calculated, and differences in means were evaluated with a paired t test. RESULTS: Successful deployment, correct positioning, and patency of the device were achieved in all patients. Procedure-related complications occurred in two (5%) patients. Thirty-day mortality rate was 20% (eight of 41 patients), and median survival time was 146 days. Laboratory values decreased significantly after the procedure (P <.001). Recurrent obstructive jaundice occurred in six (15%) patients. Primary patency rates at 3, 6, and 12 months were 90%, 76%, and 76%, respectively. Calculation of the composite end point of death or obstruction revealed a median patency duration of 138 days. No endoprosthesis migration was observed. Branch duct obstruction was observed in four (10%) patients. Postmortem examination of one stent revealed a widely patent endoprosthesis with intact covering. CONCLUSION: Initial results of percutaneous treatment of malignant biliary obstructions with fully covered ePTFE-FEP endoprostheses suggest that they are safe and potentially clinically effective.

Malignant Biliary obstruction: treatment with ePTFE-FEP-covered endoprostheses initial technical and clinical experinces in a multicenter trial / Schoder, M; Rossi, Plinio; Uflacker, R; Bezzi, Mario; Stadler, A; Funovics, Ma; Cejna, M; Lammer, J.. - In: RADIOLOGY. - ISSN 0033-8419. - STAMPA. - 225(1):(2002), pp. 35-42. [10.1148/radiol.2251011744]

Malignant Biliary obstruction: treatment with ePTFE-FEP-covered endoprostheses initial technical and clinical experinces in a multicenter trial.

ROSSI, Plinio;BEZZI, Mario;
2002

Abstract

To determine and present the initial technical and clinical results of using an expanded polytetrafluoroethylene-fluorinated ethylene propylene (ePTFE-FEP)-covered biliary endoprosthesis to treat malignant biliary obstruction. MATERIALS AND METHODS: This prospective nonrandomized study included 42 patients with malignant obstruction of the common bile duct, common hepatic duct, and hilar confluence. Unilateral (n = 38) or bilateral (n = 4) bile duct drainage was performed by using fully covered endoprostheses with anchoring fins. To avoid branch duct blockage, endoprostheses with drainage holes at the proximal end were available. Procedure- and device-related complications were recorded. Patient survival and stent patency rates were calculated with Kaplan-Meier survival analysis. Mean follow-up bilirubin and alkaline phosphatase levels were calculated, and differences in means were evaluated with a paired t test. RESULTS: Successful deployment, correct positioning, and patency of the device were achieved in all patients. Procedure-related complications occurred in two (5%) patients. Thirty-day mortality rate was 20% (eight of 41 patients), and median survival time was 146 days. Laboratory values decreased significantly after the procedure (P <.001). Recurrent obstructive jaundice occurred in six (15%) patients. Primary patency rates at 3, 6, and 12 months were 90%, 76%, and 76%, respectively. Calculation of the composite end point of death or obstruction revealed a median patency duration of 138 days. No endoprosthesis migration was observed. Branch duct obstruction was observed in four (10%) patients. Postmortem examination of one stent revealed a widely patent endoprosthesis with intact covering. CONCLUSION: Initial results of percutaneous treatment of malignant biliary obstructions with fully covered ePTFE-FEP endoprostheses suggest that they are safe and potentially clinically effective.
2002
Obstructive jaundice
01 Pubblicazione su rivista::01a Articolo in rivista
Malignant Biliary obstruction: treatment with ePTFE-FEP-covered endoprostheses initial technical and clinical experinces in a multicenter trial / Schoder, M; Rossi, Plinio; Uflacker, R; Bezzi, Mario; Stadler, A; Funovics, Ma; Cejna, M; Lammer, J.. - In: RADIOLOGY. - ISSN 0033-8419. - STAMPA. - 225(1):(2002), pp. 35-42. [10.1148/radiol.2251011744]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/256061
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 101
  • ???jsp.display-item.citation.isi??? 79
social impact